background image

-- 5 --

OF30e

WARNING

READ AND UNDERSTAND THE INSTRUCTION MANUAL BEFORE INSTALLING OR OPERATING.

ARC WELDING AND CUTTING CAN BE INJURIOUS TO YOURSELF AND OTHERS. TAKE PRECAU-

TIONS WHEN WELDING. ASK FOR YOUR EMPLOYER’S SAFETY PRACTICES WHICH SHOULD BE

BASED ON MANUFACTURERS’ HAZARD DATA.

ELECTRIC SHOCK -- Can kill

S

Install and earth the welding unit in accordance with applicable standards.

S

Do not touch live electrical parts or electrodes with bare skin, wet gloves or wet clothing.

S

Insulate yourself from earth and the workpiece.

S

Ensure your working stance is safe.

FUMES AND GASES -- Can be dangerous to health

S

Keep your head out of the fumes.

S

Use ventilation, extraction at the arc, or both, to take fumes and gases away from your breathing zone

and the general area.

ARC RAYS -- Can injure eyes and burn skin.

S

Protect your eyes and body. Use the correct welding screen and filter lens and wear protective

clothing.

S

Protect bystanders with suitable screens or curtains.

FIRE HAZARD

S

Sparks (spatter) can cause fire. Make sure therefore that there are no inflammable materials nearby.

NOISE -- Excessive noise can damage hearing

S

Protect your ears. Use earmuffs or other hearing protection.

S

Warn bystanders of the risk.

MALFUNCTION -- Call for expert assistance in the event of malfunction.

PROTECT YOURSELF AND OTHERS!

WARNING!

Read and understand the instruction manual

before installing or operating.

Do not use the power source for thawing frozen pipes.

WARNING!

This product is solely intended for arc welding.

Do not dispose of electrical equipment together with normal waste!

In observance of European Directive 2002/96/EC on Waste Electrical and Electronic

Equipment and its implementation in accordance with national law, electrical equipment

that has reached the end of its life must be collected separately and returned to an

environmentally compatible recycling facility. As the owner of the equipment, you should

get information on approved collection systems from our local representative.
By applying this European Directive you will improve the environment and human health!

GB

Summary of Contents for Origo Feed 30

Page 1: ...Valid for serial no 638 0349 301 132 070426 Feed 30 Feed 30w Origo Instruction manual...

Page 2: ...nection and control devices 8 5 2 Function explanation 10 5 3 Wire feed pressure 11 5 4 Changing loading wire 11 5 5 Flux cored wires welding 11 5 6 Aluminium wire welding 12 6 MAINTENANCE 12 6 1 Insp...

Page 3: ...3 document...

Page 4: ...operation of the welding equipment Incorrect operation of the equipment may lead to hazardous situations which can result in injury to the operator and damage to the equipment 1 Anyone who uses the we...

Page 5: ...uitable screens or curtains FIRE HAZARD S Sparks spatter can cause fire Make sure therefore that there are no inflammable materials nearby NOISE Excessive noise can damage hearing S Protect your ears...

Page 6: ...mension range 0 8 1 6 Fe SS 1 0 1 6 Al 1 0 1 6 FCW Shielding gas All types for MIG MAG max 5 bar Max diam weight of wire bobin 300 mm 18kg Dimensions lxwxh 700x255x420 Weight 14 8 kg Feed 30 with cool...

Page 7: ...ectors turning aside an arm of the pump switch ELP Hoses and appropriate connectors are marked in red and blue d Install the bobbin with electrode wire e Input the wire between the rolls and further t...

Page 8: ...ting parts can cause injury take great care To prevent the reel sliding off the hub Lock the reel in place by turning the red knob as shown on the warning label attached next to the hub WARNING When m...

Page 9: ...9 OF30e GB...

Page 10: ...switch released cut off the gas 5 2 3 Burnback time Burnback time is a delay between the time when the wire starts to brake until the time when the power source switches off the welding voltage Too sh...

Page 11: ...n approx 50 mm from the piece of wood the wire should be fed out and bend fig 2 5 4 Changing loading wire S Open the side panel S Disconnect the pressure sensor by folding it backwards the pressure ro...

Page 12: ...the customer himself attempts any work in the product during the guarantee period in order to rectify any faults 6 1 Inspection and cleaning Wire feed unit Check regularly that the wire feed unit is n...

Page 13: ...Check whether the thermal overload trip has operated indicated by the orange lamp on the power source S Check the main power supply fuses Poor welding performance S Check that the welding current sup...

Page 14: ...Diagram 14 dOF30 OrigoTM Feed 30w...

Page 15: ...OrigoTM Feed 30 Feed 30w Edition 070426 15 oOF302 Valid for serial no 638 XXX XXXX Ordering numbers 0349 304 839 OrigoTM Feed 30w 42V 1 50 60Hz 0349 304 840 OrigoTM Feed 30 42V 1 50 60Hz...

Page 16: ...9 484 355 C Drive gear 0349 484 356 D Pressure roller 0349 484 346 Fe Ss cored wire Al E Inlet nozzle 0349 308 000 Fe Ss cored wire Al F Intermediate nozzle 0349 484 344 Fe Ss cored wire Al G Outlet n...

Page 17: ...OrigoTM Feed 30 Feed 30w Edition070426 17 wOF302...

Page 18: ...OrigoTM Feed 30 Feed 30w Edition 070426 Accessories 18 aOF302 Traction kit 100 wheels set 0349 493 925 Traction kit 120 wheels set 0349 493 903...

Page 19: ...92 22 ESAB international AB Gothenburg Tel 46 31 50 90 00 Fax 46 31 50 93 60 SWITZERLAND ESAB AG Dietikon Tel 41 1 741 25 25 Fax 41 1 740 30 55 North and South America ARGENTINA CONARCO Buenos Aires...