![ESAB MobileFeed 301 AVS Instruction Manual Download Page 14](http://html1.mh-extra.com/html/esab/mobilefeed-301-avs/mobilefeed-301-avs_instruction-manual_2425077014.webp)
4 INSTALLATION
0558 012 634
- 14 -
© ESAB AB 2016
7.
Turn the wire feeder power switch to "ON".
8.
Check all gas connections for leaks.
WARNING!
Unless starting to weld, do not allow the welding wire to touch a grounded
metal surface. The welding wire becomes electrically hot when the
secondary contactor is closed. Keep fingers clear of the drive rolls; they will
start turning when the torch trigger is pressed.
9.
If gas shielded wires are used, adjust the gas flow meter to the desired flow rate by
closing the torch trigger switch or operating the gas purge switch.
10. Turn off the power source and the wire feeder when they are not in use.