SECTION 4 OPERATION
IV. OPERATION
4.1 CONTROLS (See Figure 4.1)
4.1.1 POWER SWITCH
A line toggle switch on the front panel energizes the
primary of the main transformer. This switch also turns on
the fan, which is connected across a portion of the
primary winding.
Two transformer secondary windings also become ener-
gized:
A. Gun trigger circuit 24 volts AC.
Wire feeder circuit 24 volts DC.
B. Main welding secondary circuit. Depending upon
the tap switch position, various secondary volt-
ages can be obtained. Then rectified, open circuit
voltages can be selected between 18 and 56 volts
DC when the secondary contactor is energized.
4.1.2 VOLTAGE CONTROL (Coarse Range Selector
and Fine Adjustment Range Selector)
Voltage control is by means of two high current tap
switches which connect the rectifier bridge to various
secondary taps.
The
COARSE VOLTAGE RANGE Selector
is a three-
position switch, LOW/MED/HIGH, by which the operator
selects the approximate range of voltage (or heat, that
determines the arc length) to be applied to the weld. It is
a coarse selection control and is used in conjunction with
the Fine Voltage Adjustment selector following. It must
not
be switched under load.
4.1.5
2.4.2
4.2.3
4.1.3
4.1.1
4.1.2
Torch
Cable
4.1.6
4.2.2
Secondary Output Terminals
for Welding Polarity Change-
over, see 4.1.3.
10A. Fuse
Work
Cable
Summary of Contents for MIGMASTER 250
Page 1: ...F15 087 J 04 2003 MigMaster 250 Welding Package Instruction Manual...
Page 4: ...4 TABLE OF CONTENTS...
Page 22: ...22 SECTION 3 INSTALLATION...
Page 38: ...38 Figure 5 3 Wiring Migmaster 250 for 208 230 V Model D 32861 F...
Page 39: ...39 Figure 5 4 Wiring Migmaster 250 for 208 230 380 400 460 575 V Model D 33311 D...
Page 40: ...40 SECTION 5 SERVICE...
Page 52: ...52 SECTION 6 REPLACEMENT PARTS...
Page 53: ...53 NOTES...
Page 54: ...NOTES...