![ESAB Mig 4004i Instruction Manual Download Page 15](http://html1.mh-extra.com/html/esab/mig-4004i/mig-4004i_instruction-manual_2425058015.webp)
5 OPERATION
0463 279 001
- 15 -
© ESAB AB 2015
5.1
Connections and control devices
1.
Mains power supply switch, 0 / 1
5.
Connection (+): MIG/MAG: Welding cable
MMA: Welding cable or return cable
2.
Connection for wire feed unit or remote
control unit
6.
Connection (-): MIG/MAG: Return cable
MMA: Return cable or welding cable
3.
Indicating lamp, overheating
7.
Fuse for supply voltage for feeder unit
4.
Indicating lamp, power supply ON
8.
Mains cable
5.2
Symbols
Remote control unit (2)
Over heating (3)
Power supply ON (4)
5.3
Connection of welding and return cable
The power source has two outputs, a positive terminal (+) and a negative terminal (-), for
connecting welding and return cables. The output to which the welding cable is connected
depends on the welding method or type of electrode used.
Connect the return cable to the other output on the power source. Secure the return cable's
contact clamp to the work piece and ensure that there is good contact be tween the work
piece and the output for the return cable on the power source.
For MMA welding, the welding cable can be connected to the positive terminal (+) or
negative terminal (-) depending on the type of electrode used. The connecting polar ity is
stated on the electrode packaging.
5.4
Turning the power source on/off
Turn the power source on by turning switch (1) to the ”1” position. Turn the power source off
by turning the switch (1) to the ”0” position. Regardless the mains supply is interrupted
Summary of Contents for Mig 4004i