The KHM 190 HS is an engine driven welder and is both:
a) a current source for arc welding
b) a generator of electrical current
The machine, which is powered by an internal combustion engine, is meant for industrial and professional use.
The engine is directly coupled to a three/single phase alternator. The complete assembly is mounted inside a
protective frame with lifting point using antivibration mounts.
DC welding current/voltage at duty cycle
190A/20V at 35%
160A/26.5V at 60%
120A/25V at 100%
Welding current regulation ( I scale )
(
II
scale)
A
20 – 100
90 - 190
Open circuit voltage
V
98
Welding voltage
V
20 - 27
'&:(/',1*
Electrode diameter (I scale)
(II scale)
mm
2 - 3.25
2 - 4
3/1-phase, asynchronous, self-excited, self-regulated, brushless
Insulation class
H
287387
T
400V
M
230V
M
48V
Duty cycle
%
100
100
100
Power KVA
6
5
2
Voltage
V 400
230
48
Current A
8.7
21.7
41.6
Frequency
Hz 50
50
50
$&*(1(5$725
Cos. Ø
0.8
0.8
0.8
Make / Model
HONDA / GX 390 VXB
Type / Displacement / Cylinder
- / cc / no. 4 - stroke / 3
89
/ 1
Power (**)
kW ( CV ) 8.4 (11.4)
Operating speed
rpm
3000
Cooling system
air
Engine oil capacity
liter
1.1
Starter
recoil
(1*,1(
Fuel
gasoline
Protection IP
23
Weight (*)
kg
115
Dimensions Lxwxh (*)
mm
910x525x612
*(1(5$/63(&,),&$7,21
Fuel tank capacity
liter
6.5
1RWH
T =three-phase
M =single-phase
(*) =Above values are without wheels and handles
(**)= Maximum output according to ISO 3046/1
287387$&2867,&32:(5/(9(/
+
The output indicated is guaranteed at 20°C and at a pressure of 1 bar (up to 1000 m no correction for atmosphere
pressure is required). At high temperature and above 1000 m altitude the engine output will decrease and the engine
may need adjustment for optional performances.
+
1%
at high altitudes, the standard mix air-fuel is excessively rich, the efficiency of the engine is reduced and,
therefore, the fuel consumption will increase.
+
Max. acoustic power level admitted according to the EEC norms of 17/09/84 n. 84/535-536.
The machine respects the noise limits, expressed in sound power, given in the a.m. directives.
These limits can be used to judge the sound level produced on site.
For example: the sound power level of 100 LWA.
The sound pressure (noise produced) at 7 meters distance is about 75dBA (the limit value less 25).
To calculate the sound level at other distances use this formula:
dBAx = dBAy + 10 log
At 4 meters the noise level becomes: 75 dBA + 10 log = 80 dBA
.+0+6
7(&+1,&$/'$7$$1'0$&+,1('(6&5,37,21
0
51
*%
18/10/01 25450M51GB
ry²
rx²
7²
4²
Summary of Contents for KHM 190 HS
Page 2: ......
Page 84: ...M 61 2 16 11 06 27252M61 KHM 190 HS YS WIRING DIAGRAM WELDING POWER GB...
Page 85: ...Electric System KHM 190 YS WIRING DIAGRAM AUXILIARY 400Y 230I M 61 3 29 06 06 27277 GB...
Page 86: ...M 61 4 11 9 00 27275M61 4 KHM 190 HS YS WIRING DIAGRAM WELDING POWER GB...
Page 88: ...KHM 190 HS CG 4 28 11 06 27252CG4...
Page 90: ...CG 5 28 11 06 27252CG5 KHM 190 HS...
Page 92: ...KHM 190 HS CG 6 28 5 01 27252CG6...
Page 94: ...0 6 7 28 5 01 27252 KIT DECAL...
Page 96: ......
Page 97: ......