ESAB ESABMig C280 Instruction Manual Download Page 4

 48 

2834e

1

DIRECTIVE

DECLARATION OF CONFORMITY

ESAB Welding Equipment AB, S

695 81 Laxå, Sweden, gives its unreserved guarantee that welding

power source ESABMig C280 & ESABMig C340 from serial number 225, 224 complies with standard

IEC/EN 60974

1, in accordance with the requirements of directive (73/23/EEC) and addendum

(93/68/EEC) and with standard EN 50199 in accordance with the requirements of directive

(89/336/EEC) and addendum (93/68/EEC).

−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−

Henry Selenius

Vice President

ESAB Welding Equipment AB

695 81 LAXÅ

SWEDEN

Tel: + 46 584 81000

 Fax: + 46 584 411924

Laxå 2003

03

10

2

SAFETY

Users of ESAB welding equipment have the ultimate responsibility for ensuring that anyone who

works on or near the equipment observes all the relevant safety precautions. Safety precautions

must meet the requirements that apply to this type of welding equipment. The following recommen-

dations should be observed in addition to the standard regulations that apply to the workplace.

All work must be carried out by trained personnel well

acquainted with the operation of the welding

equipment. Incorrect operation of the equipment may lead to hazardous situations which can result

in injury to the operator and damage to the equipment.
1.

Anyone who uses the welding equipment must be familiar with:

S

its operation

S

location of emergency stops

S

its function

S

relevant safety precautions

S

welding

2.

The operator must ensure that:

S

no unauthorised person is stationed within the working area of the equipment when it is

started up.

S

no

one is unprotected when the arc is struck

3.

The workplace must:

S

be suitable for the purpose

S

be free from draughts

4.

Personal safety equipment

S

Always wear recommended personal safety equipment, such as safety glasses, flame

proof

clothing, safety gloves.

S

Do not wear loose

fitting items, such as scarves, bracelets, rings, etc., which could become

trapped or cause burns.

5.

General precautions

S

Make sure the return cable is connected securely.

S

Work on high voltage equipment 

may only be carried out by a qualified electrician.

S

Appropriate fire extinquishing equipment must be clearly marked and close at hand.

S

Lubrication and maintenance must 

not 

be carried out on the equipment during operation.

GB

Summary of Contents for ESABMig C280

Page 1: ...045 040721 ESABMig C280 ESABMig C340 Bruksanvisning Brugsanvisning Bruksanvisning K ytt ohjeet Instruction manual Betriebsanweisung Manuel d instructions Gebruiksaanwijzing Instrucciones de uso Istru...

Page 2: ...rungen vorbehalten Sous r serve de modifications sans avis pr alable Recht op wijzigingen zonder voorafgaande mededeling voorbehouden Reservado el derecho de cambiar las especificaciones sin previo av...

Page 3: ...NSTALLATION 52 5 1 Placing 52 5 2 Assembly of components 52 5 3 Electrical installation 53 5 4 Mains power supply 54 6 OPERATION 55 6 1 Connection and control devices 55 6 2 Function explanation 56 7...

Page 4: ...ll acquainted with the operation of the welding equipment Incorrect operation of the equipment may lead to hazardous situations which can result in injury to the operator and damage to the equipment 1...

Page 5: ...tilation extraction at the arc or both to take fumes and gases away from your breathing zone and the general area ARC RAYS Can injure eyes and burn skin S Protect your eyes and body Use the correct we...

Page 6: ...D 4 5m S Return cable 3 5m with return clamp ESABMig C280 4WD 5m S Shelf for gas cylinder S Instruction manual 3 1 2 ESABMig C340 The power source is supplied with S Welding gun PSF 305 3m ESABMig C34...

Page 7: ...tor 0 95 0 95 Control voltage 42 V 50 60 Hz 42 V 50 60 Hz Wire feed speed 1 9 20m min 1 9 20m min Burnback time 0 0 5s 0 0 5s Creep start OFF ON OFF ON 2 4 stroke 2 4 2 4 Welding gun connection EURO E...

Page 8: ...cause radio interference It is the user s responsibility to take adequate precautions 5 1 Placing Position the welding power source such way that its cooling air inlets and outlets are not obstructed...

Page 9: ...53 2834e 5 3 Electrical installation GB...

Page 10: ...8 10 at 30 duty cycle 27 18 13 27 17 Cable area mm2 4 x 2 5 4 x 1 5 4 x 1 5 4 x 2 5 4 x 1 5 Fuse slow A 20 16 16 20 16 ESABMig C340 3 50 Hz 3 50 60 Hz 3 50 Hz 3 60 Hz 3 60 Hz Voltage V 230 400 415 500...

Page 11: ...has to be provided 6 1 Connection and control devices 1 Mains supply switch 8 Connection for return cable low induc tance 2 Switch coarse control 9 Knob for selecting creep start ON OFF 3 Switch prec...

Page 12: ...ompressed air at reduced pressure More frequently in dirty environments Otherwise the air inlet outlet may become blocked and cause overheating To avoid this you can use an airfilter The airfilter is...

Page 13: ...ata for the power source i e that the unit is not being overloaded Poor welding performance S Check that the welding current supply and return cables are correctly connected S Check that the correct c...

Page 14: ...Schema Skema Skjema Johdotuskaavio Diagram Schaltplan Sch ma Schema Esquema Schema Esquema 41 A0 L9G L9G dC2834 168 ESABMig C280 400 415V...

Page 15: ...dC2834 169 ESABMig C280 230 500V...

Page 16: ...dC2834 170 ESABMig C340 400 415V...

Page 17: ...dC2834 171 ESABMig C340 230 500V...

Page 18: ...500V 3 50Hz 230 440 460V 3 60Hz 0349 302 890 ESABMig C280 4WD 400 415V 3 50Hz 0349 302 612 ESABMig C280 4WD 230 400 415 500V 3 50Hz 230 440 460V 3 60Hz 0349 302 452 ESABMig C340 400 415V 3 50Hz 0349...

Page 19: ...be used together with item 0455 885 001 for welding with Al wire Steel must be used together with item 0455 886 001 E Outlet nozzle 0455 885 001 0455 886 001 Must be used together with item 0455 894 0...

Page 20: ...894 001 0455 889 001 Plastic must be used together with item 0455 885 001 for welding with Al wire Steel must be used together with item 0455 886 001 E Outlet nozzle 0455 885 001 0455 886 001 Must be...

Page 21: ...ar adapter 0455 053 880 C Drive gear 0455 052 001 D Inlet nozzle 0455 049 001 0335 318 001 3 0mm plastic for 0 6 1 6mm Fe Ss AL cored wire 2 4mm steel E Intermediate nozzle 0455 072 002 0456 615 001 A...

Page 22: ...r Tilbeh r Lis varusteet Accessories Zubeh r Accessoires Accessoires Accesorios Accessori Acess rios G 271 e9 7 7 H9 9 J j 89 4 aC2834 176 Digital meter 0349 302 598 Transformer kit for CO2 heater 03...

Page 23: ......

Page 24: ...l AB Gothenburg Tel 46 31 50 90 00 Fax 46 31 50 93 60 SWITZERLAND ESAB AG Dietikon Tel 41 1 741 25 25 Fax 41 1 740 30 55 North and South America ARGENTINA CONARCO Buenos Aires Tel 54 11 4 753 4039 Fax...

Reviews: