54
−
2834e
5.4
Mains power supply
Check that the unit is connected to the correct mains power supply voltage, and that
it is protected by the correct fuse size. A protective earth connection must be made,
in accordance with regulations.
Rating plate with supply connection data
ESABMig C280
3
∼
50 Hz
3
∼
50/60 Hz
3
∼
50 Hz
3
∼
60 Hz
3
∼
60 Hz
Voltage V
230
400/415
500
230
440
−
460
Current A
at 100% duty cycle
13
7
5
11
7
at 60% duty cycle
18
10
8
18
10
at 30% duty cycle
27
18
13
27
17
Cable area mm
2
4 x 2.5
4 x 1.5
4 x 1.5
4 x 2.5
4 x 1.5
Fuse slow A
20
16
16
20
16
ESABMig C340
3
∼
50 Hz
3
∼
50/60 Hz
3
∼
50 Hz
3
∼
60 Hz
3
∼
60 Hz
Voltage V
230
400/415
500
230
440
−
460
Current A
at 100% duty cycle
16
9
7
16
8
at 60% duty cycle
24
14
11
23
12
at 30% duty cycle
35
21
17
34
18
Cable area mm
2
4 x 4
4 x 2.5
4 x 2.5
4 x 4
4 x 2.5
Fuse slow
A
20
16
16
20
16
NB:
The mains cable areas and fuse sizes as shown above are in accordance with Swedish
regulations. They may not be applicable in other countries: make sure that the cable area and fuse
sizes comply with the relevant national regulations.
GB
Summary of Contents for ESABMig C280
Page 9: ...53 2834e 5 3 Electrical installation GB...
Page 15: ...dC2834 169 ESABMig C280 230 500V...
Page 16: ...dC2834 170 ESABMig C340 400 415V...
Page 17: ...dC2834 171 ESABMig C340 230 500V...
Page 23: ......