background image

 10 

C240e

6.2

Functions explanation

6.2.1

Overheating protection

When the machine is switched on with the mains switch [1], indicating lamp [4] is on and

lamp [5] off 

 the machine is ready to operate. If the internal temperature becomes too

high, the welding is interrupted and disabled. This state is indicated by lighting of the

orange indicating lamp [5] on the front of the machine. It resets automatically when the

temperature has fallen.

6.2.2

Inductance connection

Higher inductance produces a more flowing weld and fewer spatters. Lower inductance

produces a harsher sound and a stable, concentrated arc.

6.3

ESABMig C240

The ESABMig C240 is equipped with standard control unit. Welder can manually

select and adjust all welding parameters.

S

Wire speed (1,9 

 19m/min).

S

Spot

welding time.

S

Burn back time.

The machine C240 can be fitted with a digital instrument that displays current and

voltage. It incorporates a hold function (see page 19).

GB

Summary of Contents for ESABMig C240

Page 1: ...Valid for serial no 310 0349 301 064 060324 ESABMig C240 ESABMig C240s Instruction manual...

Page 2: ...2 Assembly of components 6 5 3 Electrical installation 7 5 4 Mains power supply 8 6 OPERATION 8 6 1 Connection and control devices 9 6 2 Functions explanation 10 6 3 ESABMig C240 10 6 4 ESABMig C240s...

Page 3: ...l acquainted with the operation of the welding equipment Incorrect operation of the equipment may lead to hazardous situations which can result in injury to the operator and damage to the equipment 1...

Page 4: ...tilation extraction at the arc or both to take fumes and gases away from your breathing zone and the general area ARC RAYS Can injure eyes and burn skin S Protect your eyes and body Use the correct we...

Page 5: ...Instruction manual 4 TECHNICAL DATA ESABMig C240 ESABMig C240s Voltage 230 400 415V 3 50 60Hz 230 400 415V 3 50 60Hz Permissible load at 100 duty cycle 130A 130A 60 duty cycle 170A 170A 30 duty cycle...

Page 6: ...nd outdoor use Application class The symbol indicates that the power source is designed for use in areas with increased electrical hazard 5 INSTALLATION The installation must be executed by a professi...

Page 7: ...7 C240e During transport the rear wheels of the power source are in their forward position Before use place the wheels in their rear position WARNING 5 3 Electrical installation GB...

Page 8: ...x 1 5 Fuse slow A 20 16 NB The mains cable areas and fuse sizes as shown above are in accordance with Swedish regulations They may not be applicable in other countries make sure that the cable area a...

Page 9: ...lay for welding parameters 2 Switch coarse control 12 Switch for display selection Volt or Amp 3 Switch precise control 13 Switch for display selection m min or mm 4 Indicating lamp power supply ON 14...

Page 10: ...machine It resets automatically when the temperature has fallen 6 2 2 Inductance connection Higher inductance produces a more flowing weld and fewer spatters Lower inductance produces a harsher sound...

Page 11: ...b 9 During welding process the upper row of display shows actual welding voltage or current depending on selection with switch 12 When welding process is stopped displayed values are frozen dimmed dis...

Page 12: ...g the guarantee period in order to rectify any faults 7 1 Inspection and cleaning Check regularly that the power source is free from dirt The power source should be regularly blown clean using dry com...

Page 13: ...a for the power source i e that the unit is not being overloaded Poor welding performance S Check that the welding current supply and return cables are correctly connected S Check that the correct cur...

Page 14: ...Diagram 14 dC240 ESABMig C240 230 400 415V...

Page 15: ...15 dC240 ESABMig C240s 230V...

Page 16: ...16 dC240 ESABMig C240s 400 415V...

Page 17: ...n PSF 250 3m 0349 304 659 ESABMig C240s 400 415V 3 50 60Hz welding gun PSF 250 3m 0349 304 660 ESABMig C240s 230V 3 50 60Hz welding gun PSF 250 3m 0349 305 983 ESABMig C240 400 415V 3 50 60Hz welding...

Page 18: ...used together with item 0455 885 001 for welding with Al wire Steel must be used together with item 0455 886 001 E Outlet nozzle 0455 885 001 0455 886 001 Must be used together with item 0455 894 001...

Page 19: ...ESABMig C240 ESABMig C240s Edition 060324 Accessories 19 aC240 Digital meter 0349 302 598 Transformer kit for CO2 heater 0349 302 250 Filter 0349 302 599 Cable holder 0349 303 362...

Page 20: ...AB Gothenburg Tel 46 31 50 90 00 Fax 46 31 50 93 60 SWITZERLAND ESAB AG Dietikon Tel 41 1 741 25 25 Fax 41 1 740 30 55 North and South America ARGENTINA CONARCO Buenos Aires Tel 54 11 4 753 4039 Fax...