5 OPERATION
0463 618 001
- 50 -
© ESAB AB 2019
5.12.1
Output wire-guide removal/installation
1.
Loosen the output wire-guide thumb screw (see Figure 18).
2.
Remove the output wire-guide tube out-through and out-of the CSA-adapter assembly.
3.
Replace with the new, correct-size tube in the reverse order. Do
not
tighten its
set-screw now (will be done below in "Adjustment").
5.12.2
Center wire-guide removal/installation
1.
Loosen and remove the original center wire-guide tube (see Figure 18 for location).
This center wire-guide tube removes/installs only from the left side.
2.
Install the new center wire-guide tube. Slide this tube (narrow part first and from the
left side) into its center post until it stops and hand-tighten its set screw.