3 TECHNICAL DATA
0463 618 001
- 14 -
© ESAB AB 2019
3
TECHNICAL DATA
3.1
EMP 285ic (1ph) specifications
EMP 285ic (1ph)
Voltage
230 V ±10%, 1 ph, 50/60 Hz
120 V ±10%, 1 ph, 50/60 Hz
Primary Current
I
max.
GMAW - MIG /
I
eff.
GMAW - MIG
43.0 A / 27.2 A
Breaker 20 A: 28.6 A
Breaker 15 A: 20.3 A /
Breaker 15 A: 14.6 A
I
max.
GTAW - TIG /
I
eff.
GTAW - TIG
33.1 A / 18.2 A
Breaker 15 A: 20.8 A /
Breaker 15 A: 14.7 A
I
max.
SMAW - Stick /
I
eff.
SMAW - Stick
43.6 A / 27.6 A
Breaker 15 A: 20.8 A /
Breaker 15 A: 14.7 A
Setting range (DC)
GMAW - MIG
15 A (V
out
= 14.75 V) -
300 A (V
out
= 34 V)
15 A (V
out
= 14.75 V) -
130 A (V
out
= 20.5 V)
GTAW - TIG
5 A (V
out
= 10.2 V) -
285 A (V
out
= 21.4 V)
5 A (V
out
= 10.2 V) -
200 A (V
out
= 18.0 V)
SMAW - Stick
16 A (V
out
= 20.6 V) t-
180 A (V
out
= 27.2 V)
16 A (V
out
= 20.6 V) -
130 A (V
out
= 25.2 V)
Permissible load at GMAW - MIG
100% duty cycle*
160 A (V
out
= 22 V)
Breaker 15 A: 75 A
(V
out
= 17.75 V)
Breaker 20 A: 90 A
(V
out
= 18.5 V)
60% duty cycle*
220 A (V
out
= 25 V)
Breaker 15 A: 90 A
(V
out
= 18.5 V)
Breaker 20 A: 110 A
(V
out
= 19.5 V)
40% duty cycle*
285 A (V
out
= 28 V)
Breaker 15 A: 100 A
(V
out
= 19 V)
Permissible load at GTAW - TIG
100% duty cycle*
185 A (V
out
= 17.4 V)
Breaker 15 A: 75 A
(V
out
= 17.75 V)
Breaker 20 A: 90 A
(V
out
= 18.5 V)
60% duty cycle*
240 A (V
out
= 19.6 V)
Breaker 15 A: 90 A
(V
out
= 18.5 V)
Breaker 20 A: 110 A
(V
out
= 19.5 V)
40% duty cycle*
285 A (V
out
= 21.4 V)
Breaker 15 A: 100 A
(V
out
= 19 V)
Permissible load at SMAW - Stick