![ESAB DTB 250 Instruction Manual Download Page 8](http://html1.mh-extra.com/html/esab/dtb-250/dtb-250_instruction-manual_2424973008.webp)
-- 40 --
bt10d12e
a--
Option for connecting digital or analogue voltmeter and ammeter.
b--
RP01: Current setting
MMA (A) 20--250
TIG (A) 5--250
c--
RP05: Balance control 40--60%.
d--
Q01: Power switch and lamp, HL1: The lamp light up and the fan starts at
setting ”1”.
e--
HL2: Indicates that thermal cut--out has tripped.
f--
RP03: Choice of slope--down time 0.5--10 sec.
g--
RP04: Choice of slope--up time 0.5--10 sec.
h--
SA3: Switch for selecting 2 or 4 stroke operation.
i--
SA2: Switch for selecting HF on or off.
j--
RP02: Selection of gas post--flow time 0.5--30 sec.
k--
SA4: Switch for selecting welding method and current type.
Following combinations available:
--MMA DC
--MMA AC
--TIG DC
--TIG AC
l--
SA1: Switch for selecting remote or local control of welding current.
m--
XS1: Socket for remote control or pulse unit.
n--
XS2: Central connector intended for TIG torch, providing current supply, gas and
switch in single unit.
o--
XS3: Socket for electrode holder.
p--
XS4: Socket for return cable.
bt10d
002
GB