background image

S0740 800 210/E101102/P18

- 4 -

ck10_00

TECHNICAL DATA

COOL 1

Power consumption

24V DC / 2A

Cooling power

1.3 kW  (Rating at 40 

K and 1 l/min)

Equivalent continuous A-weighted
sound pressure level

< 70 dB (A)

Coolant

Ready mixed (50% water and 50% mono-ethylene glycol)

Coolant quantity

4.5 l

Maximum flow

2.0 l/min

Maximum pressure

4 bar

Operating temperature

-10° to +40°C

Transportation temperature

-20° to +55°C

Dimensions lxwxh

610 x 256 x 256 mm

Weight 

empty

12 kg

Enclosure class

IP23

Enclosure class

The 

IP

 code indicates the enclosure class, i. e. the degree of protection against penetration by solid

objects or water. Equipment marked 

IP23

 is designed for indoor and outdoor use.

WIRING DIAGRAM

Component description

Component

Description

5

Cooling unit

5AP1

Circuit board with control electronics

5M1

Pump with motor, 24V DC

5S1

Coolant pressure switch (enclosed in pump 5M1)

5EV1

Cooling fan, 24V DC

5SL1

Flow guard. Monitoring coolant flow (option)

5XP..

Plug connector (Pin)

5XS..

Socket connector (Sleeve)

5XT..

Terminal block

Summary of Contents for COOL 1

Page 1: ...0740 800 210 Valid for serial no 033 xxx xxxx 101102 COOL 1 Service manual...

Page 2: ...g the coolant flow 6 5AP1 2 Pump motor and fan ON OFF 6 5AP1 Component positions 8 SERVICE INSTRUCTIONS 9 What is ESD 9 Service aid 9 INSTRUCTIONS 10 SAFETY 10 INSTALLATION 10 Installing to welding eq...

Page 3: ...s list as a guide to where the components are located in the equipment The spare parts list is published as a separate document see page 16 This manual contains details of design changes that have bee...

Page 4: ...ions lxwxh 610 x 256 x 256 mm Weight empty 12 kg Enclosure class IP23 Enclosure class The IP code indicates the enclosure class i e the degree of protection against penetration by solid objects or wat...

Page 5: ...S0740 800 210 E101102 P18 5 ck10_00 COOL1...

Page 6: ...at point SP3 on 20AP1 Supervision of hoses connection ELP ESAB Logic Pump is not installed in COOL1 5AP1 2 Pump motor and fan ON OFF The pump motor 5M1 and cooling fan 5EV1 are connected in parallell...

Page 7: ...S0740 800 210 E101102 P18 7 ck10_05 Pump motor and fan ON OFF Circuit diagram for pump motor and cooling fan...

Page 8: ...S0740 800 210 E101102 P18 8 ck10_05 5AP1 Component positions Component positions on the cooling unit board 5AP1 Terminal block CN4 is also named 5XT1 in the diagram...

Page 9: ...lators e g plastics generate and hold static charge so you should not bring unnecessary nonconductive items into the work area It is obviously difficult to avoid all such items so various means are us...

Page 10: ...ON The installation must be executed by a professional Location Position the cooling unit such that its air inlets and outlets are not obstructed Power supply and control COOL1 is powered and controll...

Page 11: ...S0740 800 210 E101102 P18 11 ck10i1 Assembly instructions COOL1 Aristo 300 Aristo 400 or Aristo 500...

Page 12: ...S0740 800 210 E101102 P18 12 ck10i1 Water flow guard Option...

Page 13: ...ecommended that the height from the cooling unit to the water cooled MIG MAG gun is maximum 8 5 m Water flow guard The water flow guard blocks the power source if the coolant stops flowing 0 7 l min T...

Page 14: ...d that block the pump water connections or elements Flushing can only be performed via red water connection Then drain the tank manually i e empty via the tank s filing hole Filling the coolant ESAB s...

Page 15: ...S0740 800 210 E101102 P18 15 ck10i1 Caracteristics Pump data p Pump pressure MPa Q Flow rate l min...

Page 16: ...1 l min P Power kW K Temperature difference between inlet water temperature and ambient temperature K SPARE PARTS The spare parts list is published in a separate document that can be downloaded from t...

Page 17: ...S0740 800 210 E101102 P18 17 notes NOTES...