-- 7 --
bt26d2e
5.3
Mains power supply
Make sure that the welding power source is connected to the correct supply voltage
and that it is protected by the correct fuse rating. The standards for the country in
question must be complied with as regards the mains cable area. A protective earth
connection must be made in accordance with regulations.
5.3.1
Recommended fuse sizes and minimum cable areas
Tig 150i
Tig 200i
Mains voltage
230 V
¦
10 %, 1--phase
230 V
¦
10 %, 1--fas
Mains frequency
50--60 Hz
50--60 Hz
Fuse (delayed--action)
85A 35% duty cycle MMA
120A 20% duty cycle MMA
150A 25% duty cycle MMA
10 A
16 A
20 A*)
10 A
16 A
20 A
Mains cable, area
3 x 2.5 mm
2
3x2,5 mm
2
Welding cable, area MMA
16 mm
2
16 mm
2
Welding cable, area TIG
16 mm
2
25 mm
2
*)
NOTE!
The mains plug is approved for maximum 16A.
North American version:
Mains cable is approved for maximun 18 A.
Australian- version:
The mains cable plug is approved for maximum 15A.
Note!
The cable area and fuse rating above comply with Swedish regulations. Use the welding power source
in accordance with the relevant national regulations.