background image

-- 7 --

bt26d2e

5.3

Mains power supply

Make sure that the welding power source is connected to the correct supply voltage

and that it is protected by the correct fuse rating. The standards for the country in

question must be complied with as regards the mains cable area. A protective earth

connection must be made in accordance with regulations.

5.3.1

Recommended fuse sizes and minimum cable areas

Tig 150i

Tig 200i

Mains voltage

230 V

¦

10 %, 1--phase

230 V

¦

10 %, 1--fas

Mains frequency

50--60 Hz

50--60 Hz

Fuse (delayed--action)

85A 35% duty cycle MMA

120A 20% duty cycle MMA
150A 25% duty cycle MMA

10 A
16 A

20 A*)

10 A
16 A
20 A

Mains cable, area

3 x 2.5 mm

2

3x2,5 mm

2

Welding cable, area MMA

16 mm

2

16 mm

2

Welding cable, area TIG

16 mm

2

25 mm

2

*)

NOTE!

The mains plug is approved for maximum 16A.

North American version:

Mains cable is approved for maximun 18 A.

Australian- version:

The mains cable plug is approved for maximum 15A.

Note!

The cable area and fuse rating above comply with Swedish regulations. Use the welding power source

in accordance with the relevant national regulations.

GB

Summary of Contents for Caddyt Tig 150i

Page 1: ...GB Valid for serial no 620 xxx xxxx 0459 262 201 060523 Tig 150i Tig 200i Origot TA33 Instruction manual...

Page 2: ...6 5 1 Placing 6 5 2 Rating plate 6 5 3 Mains power supply 7 6 OPERATION 8 6 1 Connections and control devices 8 6 2 Control panel TA33 9 6 3 Overheating protection 9 7 WELDING 10 7 1 TIG welding 10 7...

Page 3: ...work must be carried out by trained personnel well acquainted with the operation of the welding equipment Incorrect oper ation of the equipment may lead to hazardous situations which can result in inj...

Page 4: ...ARD S Sparks spatter can cause fire Make sure therefore that there are no inflammable materials nearby NOISE Excessive noise can damage hearing S Protect your ears Use earmuffs or other hearing protec...

Page 5: ...rmissible load at MMA 25 duty cycle 35 duty cycle 60 duty cycle 100 duty cycle 150 A 26 V 140 A 25 5 V 110 A 24 5 V 90 A 23 5 V 150 A 26 V 140 A 25 5 V 110 A 24 5 V 90 A 23 5 V Power factor at maximum...

Page 6: ...The installation must be executed by a professional WARNING This product is intended for industrial use In a domestic environment this product may cause radio interference It is the user s responsibi...

Page 7: ...10 1 phase 230 V 10 1 fas Mains frequency 50 60 Hz 50 60 Hz Fuse delayed action 85A 35 duty cycle MMA 120A 20 duty cycle MMA 150A 25 duty cycle MMA 10 A 16 A 20 A 10 A 16 A 20 A Mains cable area 3 x 2...

Page 8: ...ed to the correct supply voltage and that it is protected by the correct fuse rating 1 Mains switch 6 TIG torch connection 2 Connection gas bottle connector 7 Connection for return cable MMA 3 Mains c...

Page 9: ...E G TIG TIG HF 2 stroke MMA LiftArct 4 stroke G Slope down F Gas post flow 6 3 Overheating protection The welding power source has a thermal overload trip which operates if the temperature becomes to...

Page 10: ...s post flow Functions when using 4 stroke control of the welding torch In the 4 stroke control mode pressing the trigger switch starts gas pre flow if used 1 At the end of the gas pre flow time the cu...

Page 11: ...workpiece the arc strikes and the current rises automatically to the set value 7 1 5 Gas post flow This controls the time during which shielding gas flows after the arc is extinguished 7 1 6 Slope do...

Page 12: ...ong it will crackle and spit before finally going out com pletely If you are working on a welding bench check before attempting to strike the arc that residual waste metal pieces of electrode or other...

Page 13: ...turn cables are correctly connected S Check that the correct current value is set S Check that the correct electrodes are being used 9 1 Fault codes The Tig 150i Tig 200i comes with built in fault mon...

Page 14: ...Diagram 14 Tig150i...

Page 15: ...15 Tig150i...

Page 16: ...Diagram 16 Tig200i...

Page 17: ...17 Tig200i...

Page 18: ...200 881 Welding power source OrigotTig 150i TA33 for 230 V mains voltage 0459 200 887 Welding power source OrigotTig 150I TA33 for 230 V mains voltage Australian version 0459 200 883 Welding power sou...

Page 19: ...19 Access MMA welding and return cable kit crocodile type holder 0349 501 078 MMA welding and return cable kit screwe type holder 0349 501 079 Shoulderstrap 0459 368 880 Trolley small gas bottle 0459...

Page 20: ...22 ESAB international AB Gothenburg Tel 46 31 50 90 00 Fax 46 31 50 93 60 SWITZERLAND ESAB AG Dietikon Tel 41 1 741 25 25 Fax 41 1 740 30 55 North and South America ARGENTINA CONARCO Buenos Aires Tel...

Reviews: