![ESAB Caddy Mig C200i Instruction Manual Download Page 9](http://html1.mh-extra.com/html/esab/caddy-mig-c200i/caddy-mig-c200i_instruction-manual_2424954009.webp)
3 TECHNICAL DATA
0440 001 001
- 9 -
© ESAB AB 2020
Welding torch
MXL 180
Length
cable assembly
3.0 m
Standard control cable
2-pole
Duty cycle
The duty cycle refers to the time as a percentage of a ten-minute period that you can weld or
cut at a certain load without overloading. The duty cycle is valid for 40 °C / 104 °F, or below.
Enclosure class
The
IP
code indicates the enclosure class, i.e. the degree of protection against penetration
by solid objects or water.
Equipment marked
IP23C
is intended for indoor and outdoor use.
Application class
The symbol
indicates that the power source is designed for use in areas with increased
electrical hazard.