3 TECHNICAL DATA
0460 446 301
- 8 -
© ESAB AB 2019
3
TECHNICAL DATA
Arc 151i
Arc 201i
Mains voltage
230 V, 1 ~ 50/60 Hz
230 V, 1 ~ 50/60 Hz
Primary current:
I
max
TIG
13.8 A
24.1 A
I
max
MMA
21.3 A
24.9 A
No-load power
30 W
32 W
Voltage/current range, MMA:
A31
8 A / 20 V - 150 A / 26 V -
A33
4 A / 20 V - 150 A / 26 V 4 A / 20 V - 170 A / 26.8 V
Voltage/current range TIG
3 A / 10 V - 150 A / 16 V 3 A / 10 V - 220 A / 18 V
Permissible load at MMA:
25% duty cycle
150 A / 26.0 V
170 A / 26.8 V
60% duty cycle
100 A / 24.0 V
130 A / 25.2 V
100% duty cycle
90 A / 23.6 V
110 A / 24.4 V
Permissible load at TIG:
20% duty cycle
-
220 A / 18.8 V
25% duty cycle
150 A / 16.0 V
-
60% duty cycle
120 A / 14.8 V
150 A / 16.0 V
100% duty cycle
110 A / 14.4 V
110 A / 14.4 V
Power factor at maximum current
0.99
0.99
Efficiency at maximum current
80%
81%
Open-circuit voltage:
A31 without VRD function
1)
58 - 72 V
-
A33 VRD function deactivated
2)
56 V
56 V
VRD function activated
2)
23 V
22 V
Operating temperature
-10 °C - +40 °C
-10 °C - +40 °C
Transportation temperature
-20 °C - +55 °C
-20 °C - +55 °C
Constant A-weighted sound
pressure
< 70 dB
< 70 dB
Dimensions
(l × b × h)
418 × 188 × 208 mm
418 × 188 × 208 mm
Weight:
with A31
7.9 kg
-
with A33
8.1 kg
8.3 kg
Enclosure class
IP 23
IP 23
Application class
1) Valid for power sources without VRD specification on the rating plate.
2) Valid for power sources with VRD specification on the rating plate. The VRD function is
explained in the instruction manual for the control panel.