5 OPERATION
0460 446 301
- 11 -
© ESAB AB 2019
5
OPERATION
General safety regulations for handling the equipment can be found in the "SAFETY"
chapter of this manual. Read it through before you start using the equipment!
5.1
PFC - Power factor correction
The Caddy Arc 151i/201i are 230 V single-phase power sources equipped with a PFC circuit
making it possible to use the full range of the power source on a 16 A fuse.
The PFC also protects the power sources against fluctuating mains voltage and makes it
safer to use with a generator. Caddy Arc 151i/201i can operate with extra long mains cables,
over 100 m, giving you a very larger working radius.
5.2
Connections and control devices
1 Connection (+)
4 Connection (+)
MMA: for return cable or welding cable
MMA: for return cable or welding cable
TIG: for return cable
TIG: for Tig torch l
2 Connection for remote control unit
5 Toggle switch for mains power supply 0 / 1
3 Control panel
6 Mains cable