Cooling unit
Cooling power
2500 W at 40
˚
C temp. difference and flow1.5
l/min
Coolant
50 % water / 50% glycol
Coolant quantity
5.5 l
Maximum water flow
2.0 l/min
Maximum number of water--cooled welding
guns/torches that may be connected
two MIG welding guns or
one TIG torch and one MIG welding gun
Duty cycle
The duty cycle refers to the time as a percentage of a ten--minute period that you can weld at a cer-
tain load without overloading.
Enclosure class
The
IP
code indicates the enclosure class, i. e. the degree of protection against penetration by solid
objects or water. Equipment marked
IP23
is designed for indoor and outdoor use.
Application class
The symbol
indicates that the power source is designed for use in areas with increased
electrical hazard.
5
INSTALLATION
The installation must be executed by a professional.
WARNING!
This product is intended for industrial use. In a domestic environment this product may cause radio
interference. It is the user’s responsibility to take adequate precautions.