![ESAB AristoMig U500 Instruction Manual Download Page 10](http://html1.mh-extra.com/html/esab/aristomig-u500/aristomig-u500_instruction-manual_2424930010.webp)
-- 10 --
bu15d1ea
6.6
Remote control unit
The program version in AristoPendant U8 should be 1.20 or higher. Aristo machines
with intergral control panels should have program version 1.21 or higher, in order for
the remote control to function correctly.
When the remote control unit is connected, the power source and wire feed unit are
in remote control mode; the buttons and knobs are blocked. The functions can only
be adjusted via the remote unit.
If the remote control unit is not to be used, the remote control unit must be
disconnected from the power source / wire feed unit, as otherwise it will remain in
remote control mode.
For more information about the operation of the remote control unit, see the
operating instructions for the control panel.
7
MAINTENANCE
Regular maintenance is important for safe, reliable operation.
Maintenance must be executed by a professional.
Only those persons who have appropriate electrical knowledge (authorized
personnel) may remove the safety plates.
Note!
All guarantee undertakings from the supplier cease to apply if the customer himself
attempts any work in the product during the guarantee period in order to rectify any
faults.
7.1
Cleaning the air filter
S
Release the cover plate with the dust
filter (1).
S
Swing out the cover plate (2).
S
Remove the dust filter (3).
S
Blow it clean with compressed air at
reduced pressure.
S
Replace the filter with the finer mesh
on the side against the cover plate (2).
S
Replace the cover plate with the filter.
GB
Summary of Contents for AristoMig U500
Page 12: ...Diagram 12 bu15e11a...
Page 13: ...13 bu15e11a...
Page 14: ...14 bu15e11a Cooling unit...