-- 12 --
bm29d1ea
6.7
Replacing the AristoFeed 30 feed rollers
S
Open the side panel.
S
Disconnect the pressure sensor (1) by folding it
backwards.
S
Disconnect the pressure rollers (2) by turning the
axle (3) 1/4 turn clockwise and pulling out the axle.
The pressure rollers disconnect.
S
Disconnect the feed rollers (4) by unscrewing the
nuts (5) and pulling out the rollers.
Reassemble in the reverse order.
Selecting the correct groove in the feed rollers
Turn the feed roller so that the dimension marking of the
required groove is facing you.
6.8
Replacing the AristoFeed 48 feed rollers
S
Open the side panel.
S
Push down the pressure device (1) and pull it
towards you and upwards.
S
Pull out the bogey (2).
S
Remove the socket--head bolts (3) on the
intermediate nozzle and remove it.
S
Loosen the bolt holding the outlet nozzle (4)
and push the nozzle back.
S
Remove the socket--head bolt (5) in the centre
S
Slacken the two socket--head bolts (6) by half a turn.
S
Pull out the feed rollers (7).
Reassemble in the reverse order.
Selecting the correct groove in the
feed rollers
Place no, one or two carrier washers
between the outer washer and the feed
rollers.
NB: Replace the entire bogey
when changing the pressure rollers (8).
GB
Summary of Contents for AristoFeed 30- 4
Page 14: ...Diagram 14 bm29e11a AristoFeed 30 4 AristoFeed 48 4...
Page 15: ...15 bm29e11a...
Page 16: ...16 page...