5 OPERATION
0446 253 101
- 24 -
© ESAB AB 2020
Wire diameter (in.)
(mm)
.023
0.6
.030
0.8
.040
1.0
.045
1.2
.052
1.4
1/16
1.6
.070
1.8
5/64
2.0
3/32
2.4
Pressure setting
Wire material
Fe, Ss Tensioner unit 1
2.5
Tensioner unit 2
3–3.5
Cored Tensioner unit 1
2
Tensioner unit 2
2.5–3
Al
Tensioner unit 1
1
Tensioner unit 2
2–3
1.
Tensioner unit 1
2.
Tensioner unit 2
5.13
Wear parts storage compartment
A wear parts storage compartment can be found on the inside of the left door of the wire
feeder, for easy access to an extra set of rollers and wire guides.