5 OPERATION
0446 253 101
- 17 -
© ESAB AB 2020
5.3
Cooling liquid connection
When connecting a liquid-cooled welding torch, the main power supply switch of the power
source must be in the OFF position and the cooling unit switch must be in position 0.
Some wire feed unit variants with cooling liquid connections included, are equipped with a
detection system called ESAB Logic Pump (ELP) which checks that the water hoses are
connected. When connecting a water-cooled welding torch, the water pump starts
automatically. The detection only works with power sources that are equipped with ELP (for
instance Aristo 4004i together with Cool 1). For power sources
without
ELP function (for
instance Aristo 500ix together with Cool 2), the cooler unit must be turned on and off
manually
.
CAUTION!
Non-ELP
feeder variants should
not
be used together with power sources equipped
with ELP! If non-ELP feeders are used together with power sources equipped with
ELP, the liquid cooled torch may be damaged due to lack of coolant flow!
A liquid cooling kit can be ordered as an accessory (see the "ACCESSORIES" appendix).
Summary of Contents for Aristo Robust Feed Pulse
Page 2: ......
Page 18: ...5 OPERATION 0446 253 101 18 ESAB AB 2020 5 4 Retrofit of interconnection strain relief kit...
Page 33: ...6 CONTROL PANEL 0446 253 101 33 ESAB AB 2020...
Page 37: ...DIAGRAM 0446 253 101 37 ESAB AB 2020 DIAGRAM Robust Feed U6 Pulse...
Page 38: ...DIAGRAM 0446 253 101 38 ESAB AB 2020 Robust Feed U6 Pulse EURO Push Pull...
Page 39: ...DIAGRAM 0446 253 101 39 ESAB AB 2020 Robust Feed U6 Pulse Tweco Push Pull...