FAULT CODES
0740 801 028
- 54 -
© ESAB AB 2017
Code Description
8146 SCI communication error on power source control board
Action:
If the error persists, replace the power source control board.
8411 Motor speed error
Action:
Check that the wire feeder operates faultlessly, i.e. that the wire and the liner
runs smoothly. If the motor runs uncontrolled at a high speed, check the cables to the
motor. If the cables are OK, replace the encoder or/and the motor.
F001 Welding equipment has been stopped because of error
F003 Node error on another unit reported via CAN 2
Action:
Check the following
??? Information seams to be missing?
F004 Start weld time out
The power source was not able to start welding.
F006 Faulty wire configuration
Action:
PAB user, check wire and dimension settings.
F007 Invalid values phase shift and balance
F008 AC unit
F009 AC unit warning
F00A Supply voltage dip
Action:
Check the stability of the supply voltage.
F00B Power supply fail
Action:
Check the stability of the supply voltage.
Summary of Contents for A2-A6 PEK
Page 9: ...WIRING DIAGRAM 0740 801 028 9 ESAB AB 2017...
Page 10: ...WIRING DIAGRAM 0740 801 028 10 ESAB AB 2017 A2 A6 PEK Control Unit Serial no 628 xxx xxxx...
Page 11: ...WIRING DIAGRAM 0740 801 028 11 ESAB AB 2017...
Page 39: ...DESCRIPTION OF OPERATION 0740 801 028 39 ESAB AB 2017 26AP1 Component positions...
Page 41: ...DESCRIPTION OF OPERATION 0740 801 028 41 ESAB AB 2017 26AP2 2 Motor 1 drive Wire feed at CN7...
Page 46: ...DESCRIPTION OF OPERATION 0740 801 028 46 ESAB AB 2017 26AP2 Component positions...