CutSkill 60
OPERATING MANUAL
0-5574 4-3 OPERATION
4.02 Sequence of Operation
The following is a typical sequence of operation for this power supply. Refer to Appendix 1 for block diagram.
1. Plug the input power cord into an active circuit.
2. Switch the ON / OFF switch on the rear panel of the power source to ON position. Ensure the LCD illumi-
nates.
3. Select trigger mode between 2T and 4T. Refer to 2.05.3 for details.
Figure 4-4: Selecting Trigger Mode
4. Select cutting mode among Plate Mode, Gouging Mode and Grid Mode. Refer to 2.05.3 for details.
Figure 4-5: Selecting Cutting Mode
NOTE
Please note that when trigger mode is set at 4T, both gouging mode and grid cutting mode are unavailable.
5. Check air pressure. Press the Control Knob and enter gas purge menu (refer to Section 2.05.3) to turn
on gas purge function. The gas flows and the screen displays air pressure. Make sure the pressure is in
the correct range from 410 kPa to 550 kPa. Please note the power source has set gas pressure to 460
kPa as default value. Press the Control Knob again to stop gas flow.
6. Select Home icon and press the Control Knob to exit the menu screen.
7. Adjust output current value via control knob on the front control panel (refer to Section 2.04.2).
8. Wear protective clothing, including welding gloves and appropriate eye protection (see Table 1-1).
Summary of Contents for 1-1601-60
Page 8: ...This Page Intentionally Blank...
Page 12: ...CutSkill 60 OPERATING MANUAL GENERAL INFORMATION 1 4 0 5574 This Page Intentionally Blank...
Page 38: ...CutSkill 60 OPERATING MANUAL OPERATION 4 8 0 5574 This Page Intentionally Blank...
Page 42: ...CutSkill 60 OPERATING MANUAL SERVICE 5 4 0 5574 This Page Intentionally Blank...
Page 46: ...This Page Intentionally Blank...
Page 49: ...CutSkill 60 OPERATING MANUAL This Page Intentionally Blank...