CutSkill 60
OPERATING MANUAL
0-5574 2-1 INTRODUCTION
SECTION 2 SYSTEM:
INTRODUCTION
2.01 Working Principle
PFC
Inverter
Transformer
Rectifier
Reduce pressure, Filter
Gas Valve
Cutting Torch
Workpiece
Compressed air
A-13679
2.02 Power Supply Specifications
Power Supply Specifications
Description
CutSkill 60
Input Power
240 VAC (± 15%), Single-Phase, 50/60 Hz
Output Current
20-60 Amps, continuously
I
1max
35 Amps
I
1eff
With factory fitted supply lead & 15A plug
With upgraded 4mm
2
supply lead & 20A plug
14.3 Amps
17.3 Amps
Duty Cycle
15%
20%
60%
100%
20%
30%
60%
100%
Output Current (A)
60
60
35
30
60
60
40
35
Output Voltage (V)
120 (CW)
104 (IEC)
94 (IEC)
92 (IEC)
120 (CW) 104 (IEC)
96 (IEC)
94 (IEC)
Fan Cooled
Yes, operates continuously
Protection Class
IP23S
CutSkill 60 Power Source Gas Requirements
Recommended Input Air Pressure
600-800 kPa
(87-116 PSI)
Recommended Air Flow
110 LPM
Note 1. Duty Cycle is the percentage of time the system can be operated without overheating. Duty cycle is reduced
if primary input voltage (AC) is low or the DC voltage is higher than shown in this chart.
Note 2. Air supply must be free of oil, moisture, and other contaminants. Excessive oil and moisture may cause
double-arcing, rapid tip wear, or even complete torch failure. Contaminants may cause poor cutting performance
and rapid electrode wear. Optional filters provide increased filtering capabilities.
Table 2-1: Power Supply Specifications
NOTE
IEC Rating is determined as specified by the International Electro-Technical Commission. These specifications include calculating
an output voltage based upon power supply rated current. To facilitate comparison between power supplies, all manufacturers
use this output voltage to determine duty cycle.
CW Rating is determined using an output voltage representative of actual output voltage during cutting with a Cigweld torch.
This voltage may be more or less than IEC voltage, depending upon choice of torch, consumables, and actual cutting operation.
NOTE
In gouging mode, the maximum output current is limited to 50A.
Summary of Contents for 1-1601-60
Page 8: ...This Page Intentionally Blank...
Page 12: ...CutSkill 60 OPERATING MANUAL GENERAL INFORMATION 1 4 0 5574 This Page Intentionally Blank...
Page 38: ...CutSkill 60 OPERATING MANUAL OPERATION 4 8 0 5574 This Page Intentionally Blank...
Page 42: ...CutSkill 60 OPERATING MANUAL SERVICE 5 4 0 5574 This Page Intentionally Blank...
Page 46: ...This Page Intentionally Blank...
Page 49: ...CutSkill 60 OPERATING MANUAL This Page Intentionally Blank...