5 OPERATION
0463 613 001
- 28 -
© ESAB AB 2018
5.6.6
Set screen, analogue power source
SET
MEASURED
With AC power source: A short press on the OK button opens the
AC SETTINGS
screen.
With Aristo
®
1000 power siurce and SAW welding head: A short press on the OK
button opens a screen where the knobs will control frequency, balance and offset.
Save values and return to the
MEASURE
screen by pressing the Back button.
5.6.7
Welding menu
When any of the screens
SET
or
MEASURED
is shown, press long on OK to open
the extended
WELDING MENU
.
The information on the display depends on the authorisation level, attached power source
and welding head. The authorisation level is shown with an icon in the upper right corner of
the display.
Example of welding menu for Aristo® 1000 AC/DC
WELDING MENU
METHOD
REGULATION TYPE
START TYPE
CRATER FILL TIME
BURNBACK TIME
DC+
CA
DIRECT
O.O s
0.50 s
Example of welding menu for SAW welding with LAF or TAF
WELDING MENU
REGULATION TYPE
START TYPE
CRATER FILL TIME
BURNBACK TIME
CA
DIRECT
O.O s
0.7 s