5 OPERATION
0463 613 001
- 26 -
© ESAB AB 2018
5.6.3
Startup
1.
The software version is shown on the control panel during startup. The control panel
automatically detects the welding head during startup.
NOTE!
The welding head is identified by the welding head cable. If the cable is
replaced, use ESAB original spare part to maintain the feature.
2.
If no digital power source is attached, a menu for selecting type of analogue power
source is shown.
Previously used analogue power source is shown if on/off switch is in position II. Press
any button within 3 seconds to open the menu and change analogue power source
using the buttons Up/Down and OK.
If no button is pressed, the startup will proceed with no changes on power source.
3.
Previously selected wire type and wire dimension is shown. Press any button within 7
seconds to open the menu. Select wire type and wire dimension using the buttons
Up/Down and OK.
If no button is pressed, the control panel continues to the
SET
menu with no changes
on wire type or wire dimension.
5.6.4
Measured screen
SET
MEASURED
The
MEASURED
screen shows the measured values during welding. The information on the
screen depends on the selected welding method.
The screen shows information divided into four parts:
Method, wire, heat input Amperage
Travel speed Voltage