4 INSTALLATION
0463 709 001
- 15 -
© ESAB AB 2020
4.3
Main supply
The power source will automatically adjust to the supplied input voltage. Make sure that it is
protected by the correct fuse rating. A protective ground connection must be made, in
accordance with regulations.
1.
Rating plate with supply connection
data.
Recommended fuse sizes and minimum cable area for the MiniArc Rogue ES 180i
Power cable for heavy-duty applications (SOOW type) must be used
Supply voltage
230 VAC
120 VAC
Electrical cable area
14 AWG (2.0 mm
2
)
14 AWG (2.0 mm
2
)
Maximal current rating I
max
Stick (SMAW)
26 A
25.7 A
I1eff
Stick (SMAW)
13 A
13 A
Fuse
anti-surge type D MCB
40 A
40 A