11 - FAILURE ANALYSIS
11 - A - START UP FAILURE
11 - A - 1 - THE COMPRESSOR DOES NOT START
11 - B - RUNNING FAILURE
11 - B - 1 - THE COMPRESSOR STARTS BUT TRIPS
11 - B - 2 - THE COMPRESSOR RUNS BUT THERE IS NO DELIVERY PRESSURE
11 - B - 3 - THE COMPRESSOR OVERHEAT
Source of errors
Solution
No power supply
Check voltage
Coupling broken
Replace
Piston jams
Replace piston and fill with oil level
Source of errors
Solution
Airing broken
Replace decompression device
Loose cable
Check the wiring
Source of errors
Solution
Broken piston
Replace
Broken output valve
Replace
Source of errors
Solution
Clogged non return valve
Replace
Clogged output valve
Replace
Worn piston rings
Replace
No oil
Fill with oil