Page 22
ERVOR (SCA) - 6, Rue Désiré Granet - Z.I. du Val d'Argent - 95100 ARGENTEUIL FRANCE
(33) 01 34 11 50 00
(33) 01 34 11 50 10
Web : www.ervor.com - Email : [email protected]
Manual G06
Edition: 10/2015 - rev A
9 - PREVENTATIVE MAINTENANCE
Working hours
9 - A - DAILY
)
Drain the condensates from the air receiver.
)
Drain check valve/separator using the manual drain valve.
(Not applicable in the case of automatic drain).
9 - B - EVERY 25 HOURS
)
Check the oil level.
9 - C - AFTER THE FIRST 50 HOURS
)
Drain oil and refill with fresh oil.
9 - D - EVERY 250 HOURS
)
Replace the air intake filter.
9 - E - EVERY 500 HOURS OR EVERY YEAR
)
Drain oil and refill with fresh oil.
)
Check intake and compression valves.
9 - F - EVERY 1500 HOURS
)
Replace intake and compression valves.
)
Replace gaskets.
)
Replace the air intake filter.
)
Check the oil plug and the oil drain plug.
)
Check the cooling coil assembly.
)
Check the piston rings.
)
Check the coupling.
)
Check the cylinder heads.
)
Drain oil and refill with fresh oil.