![Erskine Attachments HP15 Operator'S Manual Download Page 8](http://html.mh-extra.com/html/erskine-attachments/hp15/hp15_operators-manual_2424489008.webp)
8
Approximate angle of fitting
SET-UP ASSEMBLY
4.
Install the #24 NPT elbow in the tank. Tighten to
approximately the angle shown. Tighten to
maximum 125 ft-lb.
IMPORTANT:
It is best for this hose to hang at a
downward angle so there is no chance of air in the
inlet hose starving the pump of oil. Be sure to
raise the tank fully before attempting to operate
the pump. Oil starvation can lead to pump
damage.
5.
Connect the pressure hose and inlet hose to the
pump assembly as shown. Use the supplied T-
bolt clamps to secure the 1-
1/2” inlet hose to the
barbed fittings. The inlet hose can be shortened
if needed, but it is best to test fit the pump on the
tractor and move the tank through the full range of
motion first.
NOTE:
Fitting angles can vary slightly depending
on the intended hose routing and distance from
the tractor.