Closing:
closing is carried out differently in accordance
with the JP1 configuration:
•
Automatic mode (JP1=ENABLE):
closing begins
automatically after standby.
•
Step-by-step mode (JP1=DISABLE):
closing begins
by briefly running the A.T. key command
(transmitter, magnetic key, key switch, etc).
In both cases, the shutter gate stops if the A.T. key
command is enabled during closing.
Closing finishes when the time programmed by way
of T.M. finishes
Dead man mode (DIP1=ON and DIP2=OFF)
Opening:
this begins by continuously pressing the A.T.
key command (push button, key switch, etc).
Standby:
the shutter gate remains open until a key
command is received.
Closing
: closing is carried out by continuously running
the C.T. key command (pushbutton, key switch, etc).
Closing finishes when C.T. is released
Dead man mode in closing (DIP1=ON and DIP2=ON)
Opening:
this begins by briefly pressing the A.T. key
command (push button, key switch, etc).
Opening finishes when the time programmed by
T.M. finishes
Standby:
the shutter gate remains open until a key
command is received.
Closing
: closing is carried out by continuously running
the C.T. key command (pushbutton, key switch, etc).
Closing finishes when C.T. is released
3
DETECTION BY PHOTOCELL OR SAFETY STRIP
Opening safety device (SG.A)
Behaviour differs in line with the operation mode
selected:
During opening in dead man mode:
if, during
opening, the opening safety device (SG.A) is enabled,
the shutter gate stops and remains on standby until
SG.A is released.
During opening in the other operation modes:
if,
during opening, the opening safety device (SG.A) is
enabled, the shutter gate inverts operation direction
and slightly closes. The shutter gate remains on standby
until a key command is received.
During closing:
the opening safety device (SG.A.) does
not run in any case.
Closing safety device (SG.C)
Behaviour differs in line with the operation mode
selected:
During opening:
the closing safety device (SG.C.) does
not run in any case.
During closing in dead man or dead man in closing
mode:
if, during closing, the closing safety device
(SG.C) is enabled, the shutter gate stops and remains
on standby until SG.C is released.
During closing in the other operation modes:
if,
during closing, the closing safety device (SG.C) is
enabled, the shutter gate inverts operation direction
and opens completely.
4
DECLARATION OF CONFORMITY
Erreka Automatismos declares that the CLEVER02/
CLEVER02M electromechanical operator has been
designed for use in a machine or for assembly along
with other elements in order to form a machine in line
with Directive 2006/42/EC.
The CLEVER02/ CLEVER02M control panels comply
with safety legislation, in line with the following
directives and regulations:
•
2006/95/CE (low voltage materials)
•
2004/108/EC (electromagnetic compatibility)
•
EN 60555-2