CLEVER01 Control panel

27

 INSTALLING AND PROGRAMMING

Operation mode selection 

Potentiometer adjustment 

 6 

STARTING UP

Final checks

Following installation and programming, start up the
shutter gate and check all the devices installed:

key commands  (transmitter,  push button  and  wall
key)

safety devices (photocells or mechanical strips)

n

If the system does not work correctly, find out
why  and  put  it  right  (see  section  “Failure
diagnosis” on page 28).

User instruction

1

Instruct  the  user  with  regards  to  the  use  and
maintenance of the installation and provide him/her
with the user guide.

2

Signpost  the  shutter  gate,  showing  that  it  opens
automatically  and  indicating  how  to  operate  it
manually.  Where  appropriate,  indicate  that
operation is using the radio transmitter.

Place J2 in the required position:

 

Step-by-step mode (J2=SEMI)

Opening  is  done  by  briefly  running  the  key
device.

Closing is done by briefly running the key device.

Automatic mode (J2= AUTO)

Opening  is  done  by  briefly  running  the  key
device.

Closing  is  carried  out  automatically  when
standby time finishes, which can be set using the
T.E. power meter

Open shutter gate standby time (T.E.) adjustment

If automatic operation mode has been programmed,
adjust 

T.E.

 to set standby time with the shutter gate

open (before automatic closing begins).

,

Minimum value: 5 seconds;  
maximum value: 140 seconds

Duration of the operations (T.M.)

The duration of the opening and closing operations is
adjusted using 

T.M.

1

Adjust  the  FCC  and  FCA  limit  switches  of  the
operator.

2

Adjust 

T.M.

  to  ensure  the  shutter  gate  completes

the  runs  (it  must  reach  the  FCC  and  FCA  limit
switches of the operator).

,

Minimum value: 1 second;  
maximum value: 70 seconds

!"##$

!"

#$%&

'()*

!"##%

)+$+

)+%+

Summary of Contents for CLEVER01

Page 1: ...E COMMANDE POUR ACTIONNEUR MONOPHAS MANUEL DE L INSTALLATEUR CONTROL PANEL FOR SINGLE PHASE OPERATOR INSTALLER S MANUAL QUADRO DE MANOBRA PARA ACCIONADOR MONOF SICO MANUAL DO INSTALADOR STEUERUNG F R...

Page 2: ..._____ 23 Declaration of Conformity ___________________________________ 23 Installing and programming 24 Tools and materials required__________________________________ 24 Initial conditions and checks_...

Page 3: ...cated in this manual is inappropriate and hazardous and could lead to accidents or failures n The installer shall be responsible for ensuring the facility is set up for its envisaged use 4 INSTALLER S...

Page 4: ...time programmed by way of T M finishes Automatic mode J2 AUTO Opening this starts by briefly pressing the A T key command transmitter magnetic key key switch etc If the key device is operated during...

Page 5: ...coincide with that of the control panel The installation must be able to support the power consumed by all the automatic key devices The installation must be earthed The electrical installation must...

Page 6: ...A Operator opening limit switch FCC Operator closing limit switch CONTROLS S1 Main switch SW1 Radio code programming mini pushbutton RSD receiver see Radio code programming on page 26 T E Standby time...

Page 7: ...l bridge between cable connectors 2 GND and 3 FT1 012 34 5 61 When using the ERREKA RSD plug in receiver decoder free receiver trinary code 433Mhz the radio code can be recorded in the control board i...

Page 8: ...that operation is using the radio transmitter Place J2 in the required position Step by step mode J2 SEMI Opening is done by briefly running the key device Closing is done by briefly running the key...

Page 9: ...SPARE PARTS n If the device needs repairing go to an authorised assistance centre or manufacturer never try to repair it yourself n Use only original spare parts 3 FAILURE DIAGNOSIS Diagnosis items L1...

Page 10: ...chnical service The operator does not work when the key devices are activated L5 lit up L2 lit up L1 off when running the A T key device The key commands signal does not reach the control board Check...

Page 11: ...Updated 18 5 11 MAINTENANCE AND DIAGNOSIS OF FAILURES 30 Installation Manual CLEVER01_CM4_EN book Page 30 Wednesday May 18 2011 12 52 PM...

Reviews: