15
ST1
FT1
P1 P2 P3
ST2
FT2
P4 P5 P6
STOP
P7 P8
P11 P12
LOCK
FCA1
FCC1
P15 P14 P16
P22 P23
Courtesy
Light
Lamp.
G7 G8
G9 G10
24Vac
G4
G5
G6
G1
G2
G3
FCA2 COM FCC2
SCA
P198W
VIVO-M201:
230Vac/50Hz (AX43)
VIVO-M201M:
125Vac/60Hz (AX43M)
N
L
POWER
MOTOR2 (G2-G1-COM)
MOTOR1 (G2-G1-COM)
T
G1/G4
G3/G6
G2/G5
AX43(M)
G1
G2 G3
G4
G5
G6
A1, A2
operators
C1, C2
capacitors (supplied installed
inside the operator)
DL4
gate opening
DL5:
gate closing
PUL1
close
mini-pushbutton
PUL2
open
mini-pushbutton
T
earth connection
Operator connections A1 / A2:
G1 / G4
open
G2 / G5
close
G3 / G6
common (COM), grey wire
When pressing PUL1, DL5 lights
up and the G2/G5 and G3/G6
cable connectors are activated.
When pressing PUL2, DL4 lights
up and the G1/G4 and G3/G6
cable connectors are activated.
Electrical connections AX43 (230V / 50Hz) and AX43M (125V / 60Hz)
For the AX43 operator we recommend using the
VIVO-M101
or
VIVO-M201
control panel.
For the AX43M operator we recommend using the
VIVO-M101M
or
VIVO-M201M
control panel.
If the
turning direction
is not
correct, interchange the G1
and G2 wires (for A1) or G4
and G5 (for A2).
ST
1
FT
1
P1 P2 P3
W
ARNING LIGHT
P9 P10
24V
ST
2
FT
2
P4 P5 P6
ST
O
P
P7 P8
GND
+
G4 G5
GND
N L
SW1
V+
P13
SNG1
P14 P15
SNG2
P16
GND
V+
P17
SNG1
P18 P19
SNG2
P20 P21 P22 P23
ENCODER1
ENCODER2
MOTOR2
G1 G2
GND
MOTOR1
P11 P12
LOCK
POWER - 230V
CN1
3
G6
G3
G7 G8
Co
ur
te
sy
Light
Lamp
.
G9 G10
-FT
(Test)
AUX
24 Vdc
P24 P25
EDGE
P198Y
V+
GND
SNG1
VIVO-D201:
VIVO-D201M:
AXS4324
T
G1/G4
G2/G5
V+
GND
SNG1
A1
Operator 1
A2
Operator 2
G1/G4
Red wire (motor)
G2/G5
Blue wire (motor)
V+
Brown wire
(encoder power supply)
GND
Mesh (encoder mass)
SNG1
Green wire (encoder signal 1)
SW1
Main switch
•
For the AXS4324 operator, programme
C305
.
•
Check that parameter
C7
is programmed for operation with encoder (
C701
).
•
Select the number of operators using
C0
(
C001
: one operator,
C002
: two operators).
Electrical connections AXS4324 (24Vdc)
Turning direction check
: after connecting the power and activating any of the key devices, the gate makes a reset
(the display shows
rS
): the gate closes until it reaches the stopper, assigning this stopper with the position "gate
closed" If it opens instead of closes during reset, change the turning direction (
C101
or
C102
for the A1 operator,
and
C201
or
C202
for the A2 operator).
We recommend the
VIVO-D201(M)
control panel.