12. Specification:
Nominal Range:
75m (245 ft)
Spectral Response:
8-14 micrometres, double filtered
Sensor:
Differential pyro-electric array
Alarm Output:
SPST relay, 10W, 0.25A, 28VDC/20VAC Transistor, NPN open
collector, 20mA/30V
Output Protection:
PTC resistor
Alarm Indicator:
Internal LED
Alarm Hold Time:
N/A
Sensitivity Adjustment:
20-140% of nominal
Temperature Compensation:
N/A
Target speed
0.2 – 5 m/s
Internal Switches:
Adaptive threshold system on/off
Supply Voltage:
10.5 to 28 VDC (nominal 12VDC)
Supply Current:
Typ. 15 mA at 12VDC
Heater Power:
N/A
Operating Temperature:
-20°C to 60°C (-4°F to 140°F)
Sealing:
Splash proof to IP64 (cable entry spray proof to IP53)
Weight:
1.2 kg (2.8 Ibs)
Dimensions:
242.5mm long x 90mm diameter
Cable Feedthrough:
Cable diameter 8-11mm (PG11)
Cable Termination:
Screw terminals
Mounting:
UBP-150, Universal mounting bracket (optional)
Test Socket:
For connection to IT44 Install. Tester