Application of the IT 44

The IT 44 is a most useful tool for checking the alignment and sensitivity setting of the detectors. It greatly
facilitates the optimisation of an installation to suit a particular site.

The IT 44 is particularly helpful in situations where a detector is operated under conditions near the
recommended operating limits of height, detection range and target speeds. The information supplied by
the IT 44 display should be used to monitor the detection performance of the detector and make
adjustments if required.

Depending on the site’s animal activity, vegetation moving in the wind and/or other sources of disturbance
it is possible that unwanted alarms occur. Monitoring and interpreting the information supplied by the IT 44
will help finding the best solution either by adjusting the alignment and/or sensitivity of the detector or by
removing disturbance sources from within the field of view.

PIRScope Software for PIR-75

For Display of Signals on a PC Screen Using the IT 44 as Interface Unit.

Procedure

1.

 

Connect the PIR-75 to power and connect the IT 44

2.

 

Connect the IT 44 output with COM port of the PC

3.

 

Load the file „PIRSCOPE.EXE“, enter language and number of COM port

4.

 

Adjust display using the keys as defined on screen

5.

 

Display will show signal amplitude (green), threshold (red) and alarm output (yellow)

6.

 

Press „H“ to save a display in the active directory. A file will be generated and saved as
„DDMMYYAB.BMP“ where AB are used for identification of files within one day.

Note

 

When walk testing the PIR-75 make sure that the 

ATD (Adaptive Threshold Decoding) is

deactivated (switch closed)

, otherwise the detection will become poor due to gradual increase of the

threshold.

 

Running „PIRSCOPE.EXE“ under Windows may lead to problems therefore exit Windows and 

start

computer under DOS

 to run the program.

Summary of Contents for PIR-75

Page 1: ...ightened to the point where it cannot be closed further with reasonable force There will then be hardly any gap between the cover and the housing considerably less than 0 5 mm The cable entry assembly...

Page 2: ...lic are suitable materials Effectiveness of a screen has to be checked by walk testing around the screen Signals from walk tests in front of the screen should still be strong while movements behind th...

Page 3: ...ity of the PIR 75 by increasing the alarm threshold level or may lead to unwanted alarms Top view The ZA P 03 alignment telescope is a convenient alignment aid giving a high degree of accuracy for ini...

Page 4: ...lower limit of the specified speed at the end of the range will produce relatively weak signals 7 Alarm Time Alarm time depends on the shape and amplitude of the alarm signal and can be as short as a...

Page 5: ...nt of the window should be removed by hand or the use of a soft instrument such as a wooden stick 11 General Comment on the PIR 75 Despite the advanced design and state of the art features of the PIR...

Page 6: ...nt 20 140 of nominal Temperature Compensation N A Target speed 0 2 5 m s Internal Switches Adaptive threshold system on off Supply Voltage 10 5 to 28 VDC nominal 12VDC Supply Current Typ 15 mA at 12VD...

Page 7: ...N FOR PIR 75 2824 00001 Page 7 Annex 1 Connector Board and Terminal Block The relay is shown in energised non alarm state ATD is activated when switch is open close switch for walk tests only Connecto...

Page 8: ...terminating screen Dimensioning a Terminating Screen From the field of view definition it becomes clear that the width of a terminating screen has to be larger than the actual figures given in the tec...

Page 9: ...ble reflections from the rising or setting sun which may generate strong signals together with fast moving clouds In cases where the screen is facing sunrise or sunset at any time of the year the top...

Page 10: ...e Installation Tester IT 44 including its version e g V 0 2 on line 1 as well as Analog Mode on line 3 for a short period of time The same display will appear every time RESET is pressed Liquid Crysta...

Page 11: ...either by adjusting the alignment and or sensitivity of the detector or by removing disturbance sources from within the field of view PIRScope Software for PIR 75 For Display of Signals on a PC Scree...