Mains connection

In order to fulfil the safety standard (IEC 60950), the mains cable must be routed via the
provided cable clip inside the BDR-510/2 box.

Mains terminal block

Cable clip

Mains cable

Mains cable

Mains cable clip

Connect the mains lead to the terminal block X2.

Make sure that the Mains Selection switch (S1) is set to match the local mains supply
(115VAC or 230VAC).

X1

X3

MAINS IN

X2

N L

MAINS

SELECT

F5

CC NC NO
Power Fail

Detect

ERNA

IN

-     +

- +

1

Ih 140

265VAC

DANGER

ACHTUNG

230

11

5

S1

XA1

XB1

- +

ERNA OUT

- +

- +

2

3

4

- +

5

- +

6

- +

7

- +

8

XG1

XC1

XD1

XE1

XF1

XH1

Mains - Live

Mains - Neutral  (Blue)
Mains - Earth  (Yellow/Green)

Mains selection switch

Mains connection

Make sure that each terminal is connected to the corresponding terminal of the mains outlet
(i.e. Phase to Phase, Neutral to Neutral and Earth to Earth). Otherwise malfunction or even
damage to the BED-108/2 will occur.
For specification of mains, refer to 

Specifications,

 at the end of these instructions.

RS485 (ERNA Camera control) input connection

The RS485 signal is connected to terminal X1.
It is important that the polarity of the connection is correct, otherwise it will not be possible
to obtain control.
Note, the RS485 input is galvanic separated from the rest of the circuit in order to avoid
ground loop problems, therefore:

DO NOT CONNECT THE SCREEN OF THE CABLE TO GROUND/EARTH!

.

RS485 (ERNA Camera control) output connection

The RS485 output signal is connected to the terminals XA1 to XH1.

Power failure connection

If an alarm in connection with mains failure is necessary, the connection can be made to
terminal X3. Potential free contacts are provided for a normally open or normally closed
output.

Installation Instructions BED-108/2