background image

Introduction

The BED-108/2 is a distribution unit made for use
with simplex RS485 or RS422 signals.
The BED-108/2 can be used in connection with all
Ernitec Telemetry Receivers series BDR-5XX and
BDR-9XX.
Using the BED-108/2 it is possible to change a
Daisy chain configuration to a Star configuration  
or a combination of both.
BED-108/2 can also be used as a repeater or as a
booster for the Telemetry Receivers BDR-51X or
BDR-91X which are normally working up to 1200
m. Using the BED-108/2 transmission distance up
to 5000 m can be achieved.

Installation

Box Installation

The BED-108/2 should be mounted at a suitable location where mains is available.
The box should be mounted on a plane surface to avoid twisting of the box, resulting in
possible leakage.

PWR

X1

X3

MAINS IN

X2

N L

MAINS

SELECT

F5

CC NC NO
Power Fail

Detect

ERNA

IN

-     +

- +

1

Ih 140

265VAC

DANGER

ACHTUNG

230

11

5

S1

Ih 1100

F6

XA1

XB1

- +

ERNA OUT

- +

- +

2

3

4

- +

5

- +

6

- +

7

- +

8

+10V

ON

0498-00053 V.0.1

XG1

XC1

XD1

XE1

XF1

H1

H2

TP1

TP2

XH1

DATA

TP3

ERNITEC

BED-108/2 RS-485 Distribution

If the box is mounted on a concrete or similar surface, use rawlplugs and galvanised
roundhead 1" screws such as no. 8 (ø4.1 x 25 mm).
If the box is mounted on a wooden surface, use galvanised roundhead 3/4" screws no. 8
(ø4.1 x 19mm) or similar.
When mounted outside, the box should be fixed with the cable glands pointing down.

Installation Instructions BED-108/2

Page 2

3020-00041

 

POWER

500 series

500 series

500 series

500 series

BED-108

1200 m

5000 m

BDR-51X = 1200 m
BDR-55X = 5000 m

5000 m

5000 m

Reviews: