background image

CE/Safety

All electronic equipment can emit or be sensitive to induced electromagnetic noise, which can
be conducted by the connected wires or transmitted as electromagnetic fields.
Electromagnetic noise can cause malfunction or damage to the equipment.
The BED-108/2 are tested to, and fulfils, the following EMC standards:

EN 50081-1 (Emission)
EN 50130-4 (Immunity)

These standards covers equipment installed in an industrial environment.

The BED-108/2 fulfil the following safety standard:

IEC 60950

BED-108/2 Layout

The BED-108/2 has been designed for easy installation and set-up. The below figure shows
the layout of the Simplex RS485 Distribution Unit.

PWR

X1

X3

MAINS IN

X2

N L

MAINS

SELECT

F5

CC NC NO
Power Fail

Detect

ERNA

IN

-     +

- +

1

Ih 140

265VAC

DANGER

ACHTUNG

230

11

5

S1

Ih 1100

F6

XA1

XB1

- +

ERNA OUT

- +

- +

2

3

4

- +

5

- +

6

- +

7

- +

8

+10V

ON

0498-00053 V.0.1

XG1

XC1

XD1

XE1

XF1

H1

H2

TP1

TP2

XH1

DATA

TP3

ERNITEC

5

6

1 2

4

3

BED-108/2 Layout

8x RS485 outputs

6

RS485 input

5

Mains failure connection

4

Mains selection switch 115/230VAC

3

Mains terminal block

2

Safety Earth connection

1

BED-108/2

No.

Description

Installation Instructions BED-108/2

Page 4

3020-00041

 

Reviews: