Function
The machine is designed for sucking and separating dry, non-combustible dust with an explosion
limit value of
>
0.1mg/m
3
.
The motor is started by the switch.
The switch has three positions:
0:
Motor off
1:
Motor on
2:
Autostart function, only 230V version
(When you use the dust
extractor together with another machine, there is an electrical outlet on the dust extractor. Connect the machine
to this outlet. Then when you start it up the dust extractor will also start. When you turn in off the dust extractor
will continue to run for approximately 20 seconds. To empty the hose.)
Dust-laden air is then sucked through the inlet valve at high speed via the suction hose. The air is
slowed down by the cyclone and coarse dust particles are separated out, partly by centrifugal force and
partly by gravity. Air and finer particles then pass through the double filter system where separation is
made. The machine is designed for filter cleaning by reverse air pulse.
The separated dust accumulates in the cyclone until the machine is switched off, when it drops through
the bottom flap into the plastic bag.
Use
Before use, the user must be trained in handling the machine and the hazardous dust.
Connect the electric plug to an outlet with the correct voltage (see the designation plate).
The filter must be cleaned from time to time. This must be done before changing the plastic bag and
can also be done when the work is complete or when there is poor suction.
Procedure:
Cover the inlet, use attached cover, let the machine build up vacuum for a few seconds
then quickly push down on the key and release it. Repeat the procedure 4-5 times.
Turn of the motor and wait until it stops completely, then uncover the inlet.
If suction remains poor, the filter should be replaced.
The plastic bag may only be replaced after cleaning the filter.
The plastic bag must be tied up after removal.
Only use original parts.
Filter change
Risk of dust dispersion - Use of personal safety equipment
Unhealthy dust can be spread during filter change. Accordingly, the user should wear protective
glasses, protective gloves, and a breathing mask conforming to protection class FFP3.
Main filter
Loosen the 3 clamps and remove the top. Lift out the filter, remove the gasket and place the filter
gently in a plastic bag. This bag must be properly disposed of.
Insert a new filter.
Only original filters may be used.
Hepa Filter
Loosen the two nuts on the filter cap carefully lift the filter into a clean plastic bag. This bag must be
properly disposed of. Insert a new filter in reverse order.
Check the seal when changing filters and change defective seals.
WARNING
Connect the electric plug to a power outlet with the correct voltage, see the nameplate.
WARNING
Switch off the machine and pull the plug out of the socket.