11. Technical Specifications
11.1. Electrical datas
SSI signal input
: singleturn or multiturn
Resolution
: 10 .. 25 bit
Code
: binary or gray
Clock output
: driver
RS 422/485
Clock input
: receiver RS 422/485
Data input
: receiver RS 422/485
Master mode
Clock frequency
: internal, 1 MHz, 500 kHz,
100 kHz or 200 kHz
Conversion rate
: approximate 28 values/second
Slave mode
Clock frequency
: external, max. 500 kHz
Break of clock brushs
: min. 500 µs
Conversion rate
: approximate 28 values/second
Digital user inputs
: 10 k
Ω
to +5 V
Logic
: NPN, max. 30 V
Signal level
: L-Pegel < 0,4 V
: H-Pegel > 3,5 V
Alarm outputs
: 2 relays (programmable as
opened contact or closed contact)
Signaling
: 2 LEDs at the front
Switch voltage
: 250 V AC / 250 V DC
Switch current
: 5 A AC / 5 A DC
Switch power
: 750 VA / 100 W
Analog output
: resolution 16 bit
Accuracy
: ± 0,2 % of final value
Voltage
: 0/2 - 10 V, max. 10 mA
Current
: 0/4 - 20 mA, max. 500
Ω
Isolation voltage
: 3 kV / 1 min
Option interface
: RS 485
Protocol
: DIN 66019 / ISO 1745
Baud rate
: 300, 1200, 2400, 4800, 9600,
19200
Data format
: 1 Start, 8 Data, N-Parity, 1 Stop
Power supply DC
: 18 .. 36 V DC
Power consumption
: approx. 200 mA
Isolation voltage
: 500 V / 1 min
34