background image

1

 Erlab R&D Laboratory

 

The engineers and chemists in our state-of-the-art R&D laboratory understand molecular filtration. We are committed to 

designing products that are safe and of the highest quality, strive to improve our products, and continuously develop new 

products that provide greater protection in the laboratory.

2

 Strict Safety Standards

 

We hold ourselves to the highest standard and adhere to the strict AFNOR NF X 15-211: 2009 filtration safety standard 

as endorsed by ANSI Z9.5-2012.

3

 A Published Chemical Listing

 

It all begins here. Without this listing, we are not compliant with AFNOR NFX 15-211. Our in-house laboratory tests, as well 

as independent testing to verify the retention capacity of over 700 chemicals for our filters.

4

 Independent Testing

 

Erlab  filters  have  been  independently  tested  multiple  times  at  various  concentrations  guaranteeing  that  our  safety 

solutions all adhere to the strict performance criteria of the AFNOR NF X 15-211:2009 standard assuring that the emission 

concentration at the filter exhaust will always be lower than 1% of the TLV.

5

 Application Questionnaire (Valiquest)

 

Our laboratory specialists will recommend the appropriate filtration fume hood, type of filter, and personalized advice.

6

 Certificate of Validation for the chemicals used in the hood

 

A certified PhD chemist issues a Certificate of Validation with a list of the chemicals approved for use in the hood.

7

 Our Safety Program

 

We back up our products 100%. This program includes your specialized chemical evaluation, validation of your hood 

upon installation, and a filtration safety specialist at your service to ensure that your hood is operating to its full potential.

We provide safety, we protect your health

Erlab invented the ductless fume hood in 1968. With more than 45 years of experience in the field of chemical filtration and 

protection of laboratory personnel; we know the formula for safety. With Erlab, you will never have to wonder or worry if our 

products are safe. We build each one of the following 7 ingredients into our products, and without all of them, your health 

and safety will be compromised.

France 

+33 (0) 2 32 09 55 80 │ [email protected]

Germany  

0800 330 47 31│ [email protected] 

China 

+86 (0) 512 5781 4085 │ [email protected]

Italy 

+39 (0) 2 89 00 771 │ [email protected]

Malaysia 

+60 (0) 7 3 555 724 │ [email protected] 

Spain 

+34 93 673 24 74 │ [email protected]

North America

+1 800-964-4434 │ [email protected]

United Kingdom

 +44 (0) 1722 341 940 │[email protected]

 www.erlab.com

About Erlab

Le laboratoire de Recherche et Développement Erlab

Halo_V04_2017_10 - Erlab France - 

Technical data ar

e not contractual.

 Erlab

®

 DFS SAS r

eser

ves the right

 to modify the pr

esent document without prior notice

.

Erlab’s state of the art Research & Development Laboratory relying exclusively on filtration

Summary of Contents for Halo Smart

Page 1: ...Halo Smart Laboratory Air Filtration System User manual Safer Simpler ...

Page 2: ...Safety notices 3 Product registration 3 Description of the unit 4 Installation 6 Connectivity principle 8 Sensors sensitivity settings 19 Replacing the filters and the Pre filter 20 Recommendations for storing and using the filters 21 ...

Page 3: ...ensors After the usage time Erlab cannot guarantee its stability and performance Product registration Take full advantage of the device s connectivity to enhance your safety Get up to 10 years warranty on your connected Erlab unit Register your product online the registration of the product will automatically give you one extra year of warranty in addition to the warranty mentioned in the Erlab ge...

Page 4: ...Halo Smart 4 Description of the unit 892 mm 35 1 8 592 mm 23 5 16 Network and power ports 4 Attachment points Side view 260 mm 10 1 4 205 mm 8 1 16 108 mm 4 1 4 98 mm 3 15 16 Above view Below view ...

Page 5: ...s Formaldehyde Semiconductor for VOCs Semiconductor of a wide array of pollutants Electro chemical sensor for acids Electro chemical sensor for Formaldehyde Smart light Simple communication by LED pulsation system e Guard Communication Remote control and monitoring App Ethernet Port 1 x RJ45 included Installation Hung via 4 eye bolts included Weight 31 kg including filter Voltage frequency 80 240V...

Page 6: ...uipment One piece overall overshoes bouffant cap Gloves Protective glasses According to the local regulations 1 Fix the unit into the hard or drop ceiling trought its 4 attachment points 2 Ceiling Air outlets must be outside the hard or drop ceiling ...

Page 7: ...User Manual 7 3 4 5 Connect the power supply and the RJ45 socket to your network 1 2 4 It is recommended to install a switch between the electrical cable and the electrical outlet 3 ...

Page 8: ...ng the product Monitoring controlling the product eGuard app Mobile PC Ethernet TCP IP Storage cabinet Air purifiers Air quality sensors eGuard app Options for connection RJ45 Access WebService Default IP address 192 168 0 200 If the network settings are changed copy the new IP address here Embedded service Flash the QR code to access usage datas of the device RJ45 RJ45 RJ45 Ethernet Routeur or an...

Page 9: ...cable 1 Apple or Android Smartphone 1 PC connected to Internet or local network Parameters Monitoring Controlling Monitoring Monitoring Controlling Data access One unit Multiple units Multiple units Historical data access Historical data download Alerts Notifications Multiple units monitoring Multiple user accounts Automatized status report except if local connection Download available on www erla...

Page 10: ...twork settings are changed copy the new IP address here _____________________ IP 192 168 0 200 Default IP address RJ45 2 Open your web browser type the following IP address 192 168 0 200 into the address bar and validate OK You are connected to the embedded software You enter the Status page and you can have access to the Settings using the following credentials Login erlab Password smart Please g...

Page 11: ...User Manual 11 Page is not accessible 1 Modify computer network parameters Right click Left click Network parameters ...

Page 12: ...Halo Smart 12 2 Access to the Network and sharing center Left click 3 Access to the network connection Right click Left click to access properties N B This confirms your WIFI is disconnected ...

Page 13: ...User Manual 13 4 Enter compatible network parameters as indicated below Left click Left click ...

Page 14: ...after the operation Enter the following parameters Validate 5 Open your web browser again type again the following IP address 192 168 0 200 and validate OK You are connected to the embedded software You enter the Status page and you can have access to the Settings using the following credentials Login erlab Password smart ...

Page 15: ...ivates smart light to identify the unit location 5 Air quality gauge indicates the air quality level green good air quality Red polluted air 6 Indicates fan status 7 ON OFF Turn ON OFF fan 8 Unit usage time since since its first usage 9 Air quality and sensor lifetime alarms 10 Volume setting 11 Embedded service version 12 Choose language 1 2 3 4 5 8 6 9 10 11 12 7 ...

Page 16: ...Halo Smart 16 Access to the settings with the following login credentials User name erlab Password smart 1 2 3 4 7 5 6 ...

Page 17: ...ches its treshold value defined in the settings Mode Day Night This operating mode sets the fan to run during Day 8am 8pm or night 8pm 8am Minimum Setpoint Min fan speed of the Min Max Detection operating mode Maximum Setpoint Max fan speed for the Min Max Detection and the Unique Detection operating modes Unique Setpoint fan speedt of the 24 7 operating mode Day Setpoint fan speed of the Day for ...

Page 18: ...Halo Smart 18 1 2 Log page details 1 Displays the device s event log 2 Used for downloading the log in csv format ...

Page 19: ...3 5 Acetone 500 1000 1 3 5 6 5 8 Methanol 200 1000 1 2 5 10 15 Ethanol 1000 5000 1 2 5 10 15 Diethyl ether 100 200 1 2 5 8 10 Halo Smart Acids version Chemical products PEL TWA 8H ppm PEL STEL ppm High sensitivity ppm Medium sensitivity ppm Low sensitivity ppm Hydrochloric acid 5 ppm 0 5 ppm 1 ppm 2 ppm Nitric acid 1 ppm 1 ppm Hydrobromic acid 2 ppm 0 5 ppm 1 ppm N B Halo Smart is not adapted to s...

Page 20: ...ing the filters and the Pre filter Pre filter replacement 1 2 3 4 5 6 1 2 US model does not have thumb screws 26 5 lbs US model does not have thumb screws New filter New pre filter Filter 12 Kg Replacing the carbon filter ...

Page 21: ...ecular filter 1 year from the date of delivery K type carbon molecular filter 1 year from the date of delivery If the maximum shelf life is reached we recommend to not install filters Predicted service life of a filter once put into use The service life of a molecular filter depends on lab air quality as well as the conditions of the environment in which it is used We recommend replacing the filte...

Page 22: ...A certified PhD chemist issues a Certificate of Validation with a list of the chemicals approved for use in the hood 7 Our Safety Program We back up our products 100 This program includes your specialized chemical evaluation validation of your hood upon installation and a filtration safety specialist at your service to ensure that your hood is operating to its full potential We provide safety we p...