Installation check-out
When installation has been completed, the unit is ready to be placed into service. Proceed as follows, while
checking the unit for any leakages:
1.
Place unit in bypass and turn on main water supply; open a cold water tap nearby and allow water to run for a
few minutes until all foreign material that may have resulted from the installation is washed out; close the tap.
2.
Slowly shift the bypass valve to the service position and secure it; allow water to completely fill the resin tank.
3.
Carefully open a cold water tap and allow water to run for at least 2 minutes to set the resin bed and purge air
from the unit; close the tap.
4.
Program the control valve according to the specific installation (refer to “Programming” on pg. 11).
5.
Press the
scroll
button repeatedly until the display shows:
6.
Leave the control valve in this position; the countdown timer will countdown to 0 sec and start a regeneration.
7.
The motor will start and the display will show:
8.
You can press the
scroll
button again to switch the motor to full speed, which will shorten the transfer time
needed by the control valve to reach the next position.
9.
The motor will move the control valve into backwash position; allow water to run to drain until all of the air is
purged from the system.
10.
Fill the brine tank with water, higher then the air-check level.
11.
Press the
scroll
button; the motor will start and the display will show:
12.
The motor will move the control valve into brine/slow rinse position; allow it to draw water from the brine tank
until the aircheck closes.
13.
Press the
scroll
button; the motor will start and the display will show:
14.
The motor will move the control valve into fast rinse/brine refill position; allow water to run to drain and brine
tank for the entire cycle time, to fill the brine tank to the programmed level.
15.
Add salt to the brine tank.
Mixing valve
To adjust the residual hardness, the incorporated mixing valve must be regulated in function of the hardness of the
incoming water and the desired residual hardness
To increase the residual hardness: turn screw counter clockwise.
To decrease the residual hardness: turn screw clockwise.
Regen in 10 sec
Rgn:XXX Cyc1: YY
Rgn:XXX Cyc2:YYY
Rgn:XXX Cyc3: YY
Summary of Contents for 2400VS Series
Page 1: ...A Division of Aquion Inc 2400VS SERIES Technical Manual...
Page 3: ...A Division of Aquion Inc Art Nr Tech_Man ENG 2400VS 2013 06...
Page 4: ......
Page 23: ...2400VS SERIES Erie Water Treatment Controls Belgium Page 19...
Page 30: ...2400VS SERIES Erie Water Treatment Controls Belgium Page 26 Valve body...
Page 33: ......