Marconi OMS 870 R3.0 Quick Reference Guide
1/1531-CRA 119 0513/30 Uen A 2007-11-15
2-38
Now you can log on to the NE with AXX 9820 CRAFT with the user
testuser
and the password
testuser
2.1.3
Assign an IP-address to the OMS 870
The OMS 870 supports remote management solutions by means of
Telnet and SNMP. The possibilities that regard to connectivity can
be rather advanced for the OMS 870, so the only explained solution
in this document is when directly connected the management-port
(MNGT). For more information refer AXX 9820 CRAFT User Guide
and Technical Reference Manual for OMS 870.
To achieve one of the above mentioned management solutions it is
necessary to assign an IP-address, subnet-mask and if required, a
default-gateway address must be defined.
2.1.3.1
System Mode
From OMS 870 R2.0 on, an additional management mode, system
mode, is added. System mode has two options IP and
IPUNNUMBERED.
Prior to configuring the IP settings on the OMS 870 the desirable
system mode should be set, since this is a strategic choice to align
with the existing design of management data communication
network. By default the system mode is IP, which means that all
physical indices must have a unique IP address and subnet mask.
Warning!
Read instructions given in “IMPORTANT - System mode from IP
to IP un-numbered” on page 2-40. Also see the AXX 9820 CRAFT
User Guide.
CLI>Management-modes\sys ?
Usage:
System-Mode
[SYSTEM-MODE=<ip|ipunnumbered>]