Marconi OMS 870 R3.0 Quick Reference Guide
1/1531-CRA 119 0513/30 Uen A 2007-11-15
1-24
Connect the Fiber Cable
1.
Remove the dust plugs from the LC (STM-n) connectors.
2.
Clean and inspect the LC jumper cable connectors.
3.
Connect the LC module input and output to the customer-
specified point.
1.8.13
Install the OMS 870 Electrical Cable
Caution!
Wear a grounding wrist strap while unpacking,handling and
interconnecting the OMS 870 equipment modules, to discharge
any static buildup.
To install electrical-connection cables in the OMS 870, connect an
electrical cable to the corresponding ports of the transmission
system. On the OMS 870 module, the electrical ports are located at
the back of the module.
All electrical cables are equipped with RJ-45 connectors. The alarm
cable is equipped with a 9 pin D-Sub connector. Ericsson
recommends that you label the electrical cable at each end to avoid
confusion with cables that are similar in appearance.
Warning!
Follow all directions and warning labels when working with
electrical cables.
Connect the Electrical Cables with RJ-45 Connector
1.
Carefully connect the electrical cables with RJ-45 connectors to
the customer-specified point.
2.
Repeat Step 1 for all other electrical cables.
3.
Guide the cables through the cable ties mounted on the sides of
the rack. The cable ties hold the cables to the side of the rack to
reduce the risk of fiber pinching.