LBI-39224
6-2
Figure 58 NETCLOCK/2 Configuration
Using the RS-232 serial connection, the CEC/IMC Manager reads the
26-character ASCII time/date data from the receiver and updates the
MOM Controller Board. The MOM then provides synchronized time
and date messages to the CIMs and consoles.
6.2 NETCLOCK INSTALLATION
The following procedures must be performed in order to implement the
NETCLOCK/2 time synchronization option:
1.
Verify a COM port on the CEC/IMC Manager is available
(COM2, COM3 or COM4).
2.
Configure Microsoft Timeserv.ini as described in
Timeserv.wri for Spectracom NETCLOCK/2
3.
Install and configure the NETCLOCK/2 in accordance with
the manufacturer's instructions.