Technical data
38
Application information
: for indoor use only, wall mounted
Enclosure class
: IP 20
Number of LTU boards
: up to max. 5
Number of cordless phones
: up to max. 40
Number of base stations
: up to max. 8
Distance to base station
: up to max. 1.9 km
Required free space around
:
above
: min. 0.2 m
to the left and to the right: min. 0.1 m
below
: min. 0.3 m
Supported baud rate
: 2400, 4800 and 9600 baud
Accessories and spare parts
RS232 cable (PC cable)
: TSRNB 101 22
Modem shell adapter
: RNTNB 102 109
Printer cable
: TSRNB 101 23
Power cable
: RPMNB 101 03/x
CSM (for Windows, softw.) : LZYNB 201 50/n
8.2
Base station BS330-GAP
Product number
: KRCNB 301 xx/n
Compliance to European regulations and standards
CE marking
:
European Council Directives : 91/263/EEC, Telecommunications Terminal
Directive
: 73/23/EEC, Low Voltage Directive
: 89/336/EEC, Electromagnetic Compatibility
Directive (EMC)
: 93/68/EEC, CE Marking Directive
DECT
: TBR6, TBR22
Safety
: EN 60950, CENELEC CLS/SC111B,
ENV 50166-2
EMC
: ETS 300 329
: EN 55022 class B
: EN 61000-4-5 (DC ports: 2 kV common
mode, 1 kV differential mode)
: EN 61000-4-2 (15 kV air discharge, 8 kV
contact discharge)
0344
Summary of Contents for DCT1800-S
Page 1: ...User s Guide DCT1800 S DECT Business Cordless Telephone System...
Page 2: ......
Page 3: ...User s Guide DCT1800 S...
Page 4: ......
Page 9: ...Contents 9 Abbreviations and glossary 41 Index 43...
Page 10: ...Contents 10...
Page 18: ...Switching the system on off 18...
Page 22: ...Checking the system 22...
Page 32: ...Using CSM 32...
Page 36: ...Preparing for remote maintenance 36...
Page 42: ...Abbreviations and glossary 42...
Page 45: ......