Technical data
52/58
5.3
Lamp sets
WARNING!
The conformity declaration applies for the specified UV
lamps and filer panels. The use of other UV lamps and filter
panels voids the operating licence.
Moreover, the UV lamps must be marked with a matching
equivalence key, see attachment page 55.
The UV lamps used are broadband radiators that can be operated with differ-
ent wattages (approx. 240-520 W).
5.3.1
INSPIRATION 400
ADVANCED PERFORMANCE
SUPER POWER
Lamp set EN
Number Description
Length
Power
Control
Order-no.
a)
3
3
UV high pressure lamps Ergoline Ultra
Filter panels Ultra Performance 862
520W
400 W / 300 W /
0 W
12645-..
1004204-..
b)
2
2
UV low pressure lamps
Ergoline TREND 8 W E19
Starter S10 (5-65 W)
8 W
8 W / 0 W
1508106-..
10047-..
c)
14
UV low pressure lamps
Ergoline TREND Advanced 120 W E8
2,00 m
120 W
120 W
1509052-..
d)
24
UV low pressure lamps
Ergoline TREND Advanced 100 W E6
1,80 m
100 W
100 W
1509050-..