
Cleaning and maintenance
42/58
4.8.2
Starter
Replace faulty starters immediately.
You can recognize a faulty starter by the blackened ends of the (UV) low
pressure lamps or when the (UV) low pressure lamps can no longer be start-
ed.
Operating a (UV) low pressure lamp with a faulty starter significantly shortens
its service life. The (UV) low pressure lamp loses power and may begin to
flicker under certain circumstances.
The starters are located in either one of the two lamp sockets or become
visible when the (UV) low pressure lamps are removed.
–
Turn 90° and carefully remove from the socket.
4.8.3
Makrolon tubes
Coloured makrolon tubes can be fitted on the accent lamps. The makrolon
tubes do not have to be changed, merely refitted with the new lamps.
–
Remove the makrolon tube from the old lamp.
–
Slide the makrolon tube onto the new lamp.
Summary of Contents for INSPIRATION 400
Page 1: ...INSPIRATION 400 GEBRAUCHSANWEISUNG OPERATING INSTRUCTIONS ...
Page 2: ......
Page 66: ...Index 64 64 ...
Page 125: ......