Cleaning and maintenance
10/2011
1007368-04
Operating instructions – 45
5.8.2
Low pressure lamps
y
Replace faulty UV low pressure lamps immediately.
y
Always replace the entire set of lamps after the specified operating time.
–
Turn 90° and carefully remove from the socket.
–
UV low pressure lamps possess a reflector which directs the light out-
wards. The lamps must be mounted in such a way that the rear side of
the reflector is located on the device side.
–
Push the pins vertically into the socket from above.
–
Turn the lamp 90°.
The lettering must be oriented towards the outside (i.e. towards the tan-
ning room or towards the user).