EG_GenPro300e_1103_IS_004
Dct_425_01
The information and non contractual pictures in this document are given for indication purposes
only. ercogener SAS reserves the right to modify its products and documentation at any time.
Inverser le pliage pour la version française.
Characteristics
Average power consumptions
@ 12 V
DC
E-GSM 900
105 mA – 415 mA pic
DCS 1 800
80 mA – 415 mA pic
GPRS 900
110 mA – 415 mA pic
GPRS 1 800
90 mA – 415 mA pic
UMTS 2100 (Band I)
210 mA
Operating conditions
Temperatures
Standard
Operating range
-20 to +60°C
Stockage range
-40 to +85°C
Humidity with no condensation
Operating range :
RH 65% ±20%
Stockage range :
5% < RH < 90 %
Atmospheric pressure :
700 hPa to 1060 hPa. (
-
400 m to 3000 m)
Weight :
90 g product only, without option.
Frequency range
mode (MHz)
Output power
(dBm)
GSM 850 / E-GSM 900
32.5 to 25
DCS 1 800 / PCS 1 900
29.5 to 24
UMTS 800 (Band VI)
23
UMTS 850 (Band V)
UMTS 900 (Band VIII)
UMTS 1 700 (Band IV)
UMTS 1 900 (Band II)
UMTS 2 100 (Band I)